MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.anl.2020.04.011

Медицинская библиотека · Auris, nasus, larynx · 2020

Wideband acoustic immitance - Absorbance measurements in ears after stapes surgery.

Niemczyk Elżbieta, Lachowska Magdalena, Tataj Emanuel, Kurczak Katarzyna, Niemczyk Kazimierz

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

The study aimed to thoroughly assess absorbance in ears after stapes surgery (stapedotomy/stapedectomy) and how stapes surgery affects wideband acoustic immittance (WAI) metrics.

METHODS

Eighty-three otosclerotic ears were analyzed pre- and postoperatively. The analysis comprised: air-bone gap (ABG) and WAI which included absorbance measurements, resonance frequency assessment, low frequency tympanometry and metrics derived from these measures.

RESULTS

Absorbance after stapes surgery changed considerably compared to otosclerotic ears before surgery and also differed from normal ears. Absorbance after stapes surgery revealed two significantly different plot types: single-low-frequency-peak absorbance and two-peaks absorbance. Stapes surgery reduced resonance frequency in majority of operated ears and increased static compliance in low frequency tympanometry. Static compliance difference was directly proportional to ABG improvement at low frequencies. Postoperative ABG at 250 Hz and 500 Hz was most commonly correlated with postoperative WAI parameters. ABG improvement at 3000 Hz and 4000 Hz was directly proportional to absorbance difference at ~3000 Hz and 4000 Hz. It influenced the width of the postoperative absorbance by shifting both sides of the plot (negative values shift the points of the plot toward lower frequencies) with the correlation being more pronounced in postoperative two-peaks absorbance type ears.

CONCLUSIONS

Absorbance by itself is not sufficient for assessment of changes to middle function following stapes surgery, and should be complemented with other measures. WAI measurements including absorbance, resonance frequency assessment, low frequency tympanometry, and metrics derived from these measures combined with air-bone gap provide insight into mechano-acoustic changes in the middle-ear system as a result of stapes surgery.

Для цитирования: Niemczyk Elżbieta, Lachowska Magdalena, Tataj Emanuel, Kurczak Katarzyna, Niemczyk Kazimierz. Wideband acoustic immitance - Absorbance measurements in ears after stapes surgery.. Auris, nasus, larynx. 2020. DOI: 10.1016/j.anl.2020.04.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.