MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.carrev.2019.04.023

Медицинская библиотека · Cardiovascular revascularization medicine : including molecular interventions · 2019

Clinical Outcomes of Sentinel Cerebral Protection System Use During Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.

Ndunda Paul M, Vindhyal Mohinder R, Muutu Tabitha M, Fanari Zaher

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

OBJECTIVE

To compare the clinical outcomes following transcatheter aortic valve replacement (TAVR) with and without the use of the Sentinel Cerebral Protection System (Sentinel CPS).

BACKGROUND

Stroke occurs in 2-5% of patients at 30 days after TAVR and increases mortality >3 fold. The Sentinel CPS is the only FDA (Food and Drug Administration) approved cerebral embolic protection device.

METHODS

The Cochrane Library, PubMed and Web of Science were searched for relevant studies for inclusion in the meta-analysis. Two authors independently screened and included studies comparing the clinical outcomes after TAVR with and without the Sentinel CPS. Risk of bias was assessed using the Cochrane tools (RoB2.0 and ROBINS-I).

RESULTS

Four studies comparing 606 patients undergoing TAVR with Sentinel CPS to 724 without any embolic protection device were included. Sentinel CPS use was associated with lower rates of 30-day mortality [0.8% vs 2.7%; RR 0.34 (95% CI 0.12, 0.92) I2 = 0%], 30-day symptomatic stroke [3.5% vs 6.1%; RR 0.51 (95% CI 0.29, 0.90) I2 = 0] and major or life-threatening bleeding [3.3% vs 6.6%; RR 0.50 (0.26, 0.98) I2 = 16%]. There was no significant difference between the two arms in the incidence of acute kidney injury [0.8% vs 1%; RR 0.85 (95% CI 0.22, 3.24) I2 = 0%] and major vascular complications [5.1% vs 6%; RR 0.74 (0.33, 1.67) I2 = 45%].

CONCLUSION

The results suggest that Sentinel CPS use in TAVR is associated with a lower risk of stroke, mortality and major or life-threatening bleeding at 30 days.

Для цитирования: Ndunda Paul M, Vindhyal Mohinder R, Muutu Tabitha M, Fanari Zaher. Clinical Outcomes of Sentinel Cerebral Protection System Use During Transcatheter Aortic Valve Replacement: A Systematic Review and Meta-Analysis.. Cardiovascular revascularization medicine : including molecular interventions. 2019. DOI: 10.1016/j.carrev.2019.04.023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.