m+Medelevator.RU
← Поиск публикаций
Circulation. Cardiovascular interventions · 2019

Assessment of Long-Term Structural Deterioration of Transcatheter Aortic Bioprosthetic Valves Using the New European Definition.

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Durand Eric, Sokoloff Anastasia, Urena-Alcazar Marina, Chevalier Bernard, Chassaing Stephan, Didier Romain, Tron Christophe, Litzler Pierre-Yves, Bouleti Claire, Himbert Dominique, Hovasse Thomas, Bar Olivier, Avinée Guillaume, Iung Bernard, Blanchard Didier, Gilard Martine, Cribier Alain, Lefevre Thierry, Eltchaninoff Hélène

Аннотация

BACKGROUND: The durability of transcatheter aortic bioprosthetic valves is a crucial issue, but data are scarce, especially beyond 5 years of follow-up. We aimed to assess long-term (7 years) structural valve deterioration (SVD) and bioprosthetic valve failure of transcatheter aortic bioprosthetic valves.

METHODS AND RESULTS: Consecutive patients with at least 5-year follow-up available undergoing transcatheter aortic valve implantation from April 2002 to December 2011 in 5 French centers were included. Incidence of SVD and bioprosthetic valve failure were defined according to newly standardized criteria of the European Association of Percutaneous Cardiovascular Interventions/European Society of Cardiology/European Association for Cardio-Thoracic Surgery and reported as cumulative incidence function to account for the competing risk of death. One thousand four hundred three consecutive patients were included with a mean age of 82.6±7.5 years and with a mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) of 21.3±7.5%. A balloon-expandable valve was used in 83.7% of cases. Survival rates were 83.5% (95% CI, 81.4%-85.5%) and 18.6% (95% CI, 15.3%-21.8%) at 1 and 7 years, respectively. Median duration of follow-up was 3.9 years. Bioprosthetic valve failure occurred in 19 patients with a 7-year cumulative incidence of 1.9% (95% CI, 1.4%-2.4%). SVD occurred in 49 patients (moderate, n=32; severe, n=17) with a 7-year cumulative incidence of moderate and severe SVD of 7.0% (95% CI, 5.6%-8.4%) and 4.2% (95% CI, 2.9%-5.5%), respectively. Five patients had aortic valve reintervention (1.0%; 95% CI, 0.4%-1.6%) including 1 case of surgical aortic valve replacement and 4 redo-transcatheter aortic valve implantation. The incidences of SVD and bioprosthetic valve failure were not significantly different between balloon and self-expandable prostheses.

CONCLUSIONS: The long-term assessment of transcatheter aortic bioprosthetic valves durability is limited by the poor survival of our population beyond 5 years. Further studies are warranted, particularly in younger and lower-risk patients.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты