MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1532/hsf.5621

Медицинская библиотека · The heart surgery forum · 2023

Impact of Indexed Effective Orifice Area on the Quality of Life of Patients after Aortic Valve Replacement.

Gursoy Mete, Yaşar Emre, Guler Salih, Yalcin Lokman, Muradli Tural, Kadirogullari Ersin, Kutluk Erhan, Aydin Unal

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Improving health related quality of life is an important goal of aortic valve replacement. Inadequate effective orifice area of prosthesis according to the patient's body surface area may be associated with poor outcomes. In this study, we aimed to analyze impact of indexed effective orifice area (iEOA) on patients' quality of life after aortic valve replacement.

METHODS

A total of 138 patients who underwent isolated aortic valve replacement were included to the study. Quality of life assessment was performed with EuroQol Group EQ-5D-5L questionnaire. Patients were divided into three groups based on iEOA (Group 1 had an iEOA of <0.65 cm2/m2 (19 patients), Group 2 had an iEOA between 0.65-0.85 cm2/m2 (71 patients), and Group 3 had an iEOA of >0.85 cm2/m2). Mean EQ-5D-5L scores were compared among the groups statistically.

RESULTS

Mean EQ-5D-5L scores were lower in Group 1 than in Groups 2 and 3 (Group 1: 0.72 ± 0.18, Group 2: 0.83 ± 0.20, and Group 3: 0.86 ± 0.9, p = 0.044 and p = 0.014). The EQ-5D-5L score was significantly lower in patients with a ≥20 mmHg transvalvular gradient than those with a <20 mmHg (0.74 ± 0.25 vs. 0.84 ± 0.18, p = 0.014).

CONCLUSIONS

Our results show that an iEOA <0.65 cm2/m2 is significantly associated with impaired postoperative health-related quality of life. Newer generation prostheses, transcatheter valve implantation, and root enlargement techniques should be kept in mind in preoperative planning.

Для цитирования: Gursoy Mete, Yaşar Emre, Guler Salih, Yalcin Lokman, Muradli Tural, Kadirogullari Ersin, Kutluk Erhan, Aydin Unal. Impact of Indexed Effective Orifice Area on the Quality of Life of Patients after Aortic Valve Replacement.. The heart surgery forum. 2023. DOI: 10.1532/hsf.5621.