DOI 10.7754/clin.lab.2018.180637
Interference of High Dose Biotin Supplementation with Thyroid Parameters in Immunoassays Utilizing the Interaction between Streptavidin and Biotin: a Case Report and Review of Current Literature.
Аннотация
BACKGROUND
Automated immunoassays utilizing the interaction between streptavidin and biotin are widely used. Nonetheless, biotin remains an often overlooked confounder.
METHODS
We report the case of a 54-year-old female patient with progressive multiple sclerosis and Hashimoto's thyroiditis who presented herself for a follow-up. Measurements on Roche's cobas® 8000 modular analyzer series suggested severe hyperthyroidism. Initially, no relevant confounders could be identified.
RESULTS
All requested thyroid parameters were measured with alternative methods, yielding plausible results.
CONCLUSIONS
Biotin is a significant confounder in many immunoassays. Alternative measurement methods or methods of biotin neutralization need to be implemented for certain situations.