Quantitative EEG signatures of delirium and coma in mechanically ventilated ICU patients.

Williams Roberson Shawniqua, Azeez Naureen A, Fulton Jenna N, Zhang Kevin C, Lee Aaron X T, Ye Fei, Pandharipande Pratik, Brummel Nathan E, Patel Mayur B, Ely E Wesley

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To identify quantitative electroencephalography (EEG)-based indicators of delirium or coma in mechanically ventilated patients.

METHODS

We prospectively enrolled 28 mechanically ventilated intensive care unit (ICU) patients to undergo 24-hour continuous EEG, 25 of whom completed the study. We assessed patients twice daily using the Richmond Agitation-Sedation Scale (RASS) and Confusion Assessment Method for the ICU (CAM-ICU). We evaluated the spectral profile, regional connectivity and complexity of 5-minute EEG segments after each assessment. We used penalized regression to select EEG metrics associated with delirium or coma, and compared mixed-effects models predicting delirium with and without the selected EEG metrics.

RESULTS

Delta variability, high-beta variability, relative theta power, and relative alpha power contributed independently to EEG-based identification of delirium or coma. A model with these metrics achieved better prediction of delirium or coma than a model with clinical variables alone (Akaike Information Criterion: 36 vs 43, p = 0.006 by likelihood ratio test). The area under the receiver operating characteristic curve for an ad hoc hypothetical delirium score using these metrics was 0.94 (95%CI 0.83-0.99).

CONCLUSIONS

We identified four EEG metrics that, in combination, provided excellent discrimination between delirious/comatose and non-delirious mechanically ventilated ICU patients.

SIGNIFICANCE: Our findings give insight to neurophysiologic changes underlying delirium and provide a basis for pragmatic, EEG-based delirium monitoring technology.

Для цитирования: Williams Roberson Shawniqua, Azeez Naureen A, Fulton Jenna N, Zhang Kevin C, Lee Aaron X T, Ye Fei, Pandharipande Pratik, Brummel Nathan E, Patel Mayur B, Ely E Wesley. Quantitative EEG signatures of delirium and coma in mechanically ventilated ICU patients.. Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology. 2022. DOI: 10.1016/j.clinph.2022.11.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.