Ultrasonic Cavity Preparation with CVD Diamond Tips: A Scanning Electron Microscopy Study of Dentin Surface Morphology and Smear Layer Formation.

Schneider Mauricio, Melo de Matos Jefferson David, Coelho Sinhoreti Mário Alexandre, Peiter Diego Telomaro, Bastian José Eduardo, Queiroz Daher Antonio

СтатьяОбзорПеревод в очереди

Аннотация

BACKGROUND

Minimally invasive dentistry has driven the development of alternative cavity preparation techniques aimed at preserving tooth structure and improving biological outcomes. Ultrasonic systems associated with chemical vapor deposition (CVD) diamond tips have emerged as a potential alternative to conventional rotary instruments; however, evidence regarding their effects on dentin surface morphology and smear layer characteristics under SEM remains limited. This study aimed to evaluate the morphological characteristics of dentin surfaces after cavity preparation using ultrasonic and conventional rotary techniques.

MATERIALS AND

METHODS

Twenty extracted human teeth were sectioned longitudinally to obtain standardized specimens. Samples were assigned to ultrasonic preparation using CVD diamond tips or conventional rotary preparation using carbide burs at high and low speeds. After preparation, specimens were cleaned, stored in distilled water, sputter-coated, and analyzed by scanning electron microscopy (SEM). Surface morphology, smear layer presence, and dentinal tubule exposure were qualitatively assessed at different magnifications.

RESULTS

Ultrasonic preparation resulted in consistently cleaner dentin surfaces with minimal smear layer and open dentinal tubules, whereas conventional rotary instrumentation produced irregular surfaces covered by dense smear layer and debris.

CONCLUSIONS

Ultrasonic cavity preparation using CVD diamond tips demonstrated superior surface characteristics compared with conventional rotary techniques, supporting its potential as a minimally invasive approach that may enhance adhesion and preserve dentin-pulp integrity.

Для цитирования: Schneider Mauricio, Melo de Matos Jefferson David, Coelho Sinhoreti Mário Alexandre, Peiter Diego Telomaro, Bastian José Eduardo, Queiroz Daher Antonio. Ultrasonic Cavity Preparation with CVD Diamond Tips: A Scanning Electron Microscopy Study of Dentin Surface Morphology and Smear Layer Formation.. Journal of clinical and experimental dentistry. 2026. DOI: 10.4317/jced.64155.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.