DOI 10.1016/j.jcct.2018.10.009
Iliofemoral artery lumen volume assessment with three dimensional multi-detector computed tomography and vascular complication risk in transfemoral transcatheter aortic valve replacement.
Аннотация
BACKGROUND
Transfemoral Transcatheter Aortic Valve Replacement (TAVR) carries a risk of Vascular Complications (VCs) at the access site. The currently used measures for assessing the risk for VCs are not accurate enough, and sometimes fail to predict them. We therefore aimed to examine whether Iliofemoral artery lumen volume (IFV) assessment with 3-dimensional computed tomography (CT) predicts VCs after transfemoral TAVR.
METHODS
We identified 45/560 trans-femoral TAVR patients with VC, then performed nearest neighbor 1:1 matching for patients with no VC, matching for age, sex, TAVR year, valve size and type, closure-device, sheath size and peripheral vascular disease. IFV, minimal diameter, tortuosity, and calcification were measured, and their diagnostic performance assessed.
RESULTS
The final analysis included 45 patients with and 45 patients without VCs. The two groups were well balanced. For all patients, median IFV was 8.65 ml (IQR 6.5-11.95). IFV was lower in patients with VC compared to patients without VC: 7.10 ml (IQR 5.4-9.0) vs. 10.10 ml (IQR 8.3-13.3), p < 0.001. VC risk had marginal association with iliofemoral artery minimal diameter (p = 0.06) and no association with tortuosity or calcification. Compared with other measurements, IFV had the most favorable receiver operating curve for the prediction of VC, with an area under the curve (AUC) of 0.78.
CONCLUSION
IFV measurement using 3-dimensional CT is significantly associated with VCs in transfemoral TAVR patients and might be superior to currently accepted parameters. IFV should be further studied among extended cohorts of TAVR treated patients as a novel tool for VC risk assessment prior to transfemoral TAVR.