Magnetic resonance in medicine · 2018
Whole-heart spiral simultaneous multi-slice first-pass myocardial perfusion imaging.
СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yang Yang, Meyer Craig H, Epstein Frederick H, Kramer Christopher M, Salerno Michael
Аннотация
PURPOSE: To develop and evaluate a simultaneous multislice (SMS) spiral perfusion pulse sequence with whole-heart coverage.
METHODS: An orthogonal set of phase cycling angles following a Hadamard pattern was incorporated into a golden-angle (GA) variable density spiral perfusion sequence to perform SMS imaging at different multiband (MB) factors. Images were reconstructed using an SMS extension of L1-SPIRiT that we have termed SMS-L1-SPIRiT. The proposed sequence was evaluated in 40 subjects (10 each for MB factors of 1, 2, 3, and 4). Images were blindly graded by 2 cardiologists on a 5-point scale (5, excellent). To quantitatively evaluate the reconstruction performance against images acquired without SMS, the MB =1 data were used to retrospectively simulate data acquired at MB factors of 2 to 4.
RESULTS: Analysis of the SMS point-spread function for the desired slice showed that the proposed sampling strategy significantly canceled the main-lobe energy of the other slices and has low side-lobe energy resulting in an incoherent temporal aliasing pattern when rotated by the GA. Retrospective experiments demonstrated the SMS-L1-SPIRiT method removed aliasing from the interfering slices and showed excellent agreement with the ground-truth MB =1 images. Clinical evaluation demonstrated high-quality perfusion images with average image-quality scores of 4.3 ± 0.5 (MB =2), 4.2 ± 0.5 (MB =3), and 4.4 ± 0.4 (MB =4) with no significant quality difference in image quality between MB factors (P = 0.38).
CONCLUSION: SMS spiral perfusion at MB factors 2, 3, and 4 produces high-quality perfusion images with whole-heart coverage in a clinical setting with high sampling efficiency.
METHODS: An orthogonal set of phase cycling angles following a Hadamard pattern was incorporated into a golden-angle (GA) variable density spiral perfusion sequence to perform SMS imaging at different multiband (MB) factors. Images were reconstructed using an SMS extension of L1-SPIRiT that we have termed SMS-L1-SPIRiT. The proposed sequence was evaluated in 40 subjects (10 each for MB factors of 1, 2, 3, and 4). Images were blindly graded by 2 cardiologists on a 5-point scale (5, excellent). To quantitatively evaluate the reconstruction performance against images acquired without SMS, the MB =1 data were used to retrospectively simulate data acquired at MB factors of 2 to 4.
RESULTS: Analysis of the SMS point-spread function for the desired slice showed that the proposed sampling strategy significantly canceled the main-lobe energy of the other slices and has low side-lobe energy resulting in an incoherent temporal aliasing pattern when rotated by the GA. Retrospective experiments demonstrated the SMS-L1-SPIRiT method removed aliasing from the interfering slices and showed excellent agreement with the ground-truth MB =1 images. Clinical evaluation demonstrated high-quality perfusion images with average image-quality scores of 4.3 ± 0.5 (MB =2), 4.2 ± 0.5 (MB =3), and 4.4 ± 0.4 (MB =4) with no significant quality difference in image quality between MB factors (P = 0.38).
CONCLUSION: SMS spiral perfusion at MB factors 2, 3, and 4 produces high-quality perfusion images with whole-heart coverage in a clinical setting with high sampling efficiency.
Предметные рубрики MeSH
AdultAlgorithmsArrhythmias, CardiacAtrial FibrillationCardiomyopathiesCardiomyopathy, HypertrophicComputer SimulationFemaleHeartHumansImage EnhancementImage Interpretation, Computer-AssistedMiddle AgedMyocardial InfarctionMyocardial Perfusion ImagingMyocarditisObserver VariationPericardiumReproducibility of ResultsRetrospective StudiesTachycardia, VentricularVentricular Dysfunction, RightVentricular Premature Complexes