PloS one · 2018
Prognostic value of pre-procedural left ventricular strain for clinical events after transcatheter aortic valve implantation.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Suzuki-Eguchi Noriko, Murata Mitsushige, Itabashi Yuji, Shirakawa Kousuke, Fukuda Memori, Endo Jin, Tsuruta Hikaru, Arai Takahide, Hayashida Kentaro, Shimizu Hideyuki, Fukuda Keiichi
Аннотация
BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an alternative therapy for surgically high-risk patients with severe aortic stenosis (AS). Although TAVI improves survival of patients with severe AS, the mechanism of this effect remains to be clarified. We investigated the effects of TAVI on left ventricular (LV) function and identified the predictive parameters for cardiac events after TAVI.
METHODS AND RESULTS: We studied 128 patients with severe symptomatic AS who underwent TAVI. Echocardiographic assessments were performed before and after TAVI. In addition to the conventional echocardiographic parameters such as LV ejection fraction (LVEF) and LV mass index (LVMI), the LV global longitudinal strain (GLS) and early diastolic peak strain rate (SR_E) using two-dimensional speckle tracking echocardiography were also evaluated. All patients were assessed for clinical events including major adverse cardiac events and stroke according to Valve Academic Research Consortium-2 criteria. GLS, early diastolic peak velocity (e'), aortic regurgitation (AR) severity, and SR_E were significantly improved after TAVI. Thirteen patients had an event during the observational period of 591 days (median). Patients with events had higher LVMI, more severe AR, and worse GLS compared to those without events. Furthermore, receiver-operating curve analysis revealed that GLS was the strongest predictor for clinical events (p = 0.009; area under the curve, 0.73).
CONCLUSION: Preoperative LV geometric deformation and dysfunction, as a consequence of the cumulative burden of pressure overload, improved after TAVI and could predict cardiac events after TAVI.
METHODS AND RESULTS: We studied 128 patients with severe symptomatic AS who underwent TAVI. Echocardiographic assessments were performed before and after TAVI. In addition to the conventional echocardiographic parameters such as LV ejection fraction (LVEF) and LV mass index (LVMI), the LV global longitudinal strain (GLS) and early diastolic peak strain rate (SR_E) using two-dimensional speckle tracking echocardiography were also evaluated. All patients were assessed for clinical events including major adverse cardiac events and stroke according to Valve Academic Research Consortium-2 criteria. GLS, early diastolic peak velocity (e'), aortic regurgitation (AR) severity, and SR_E were significantly improved after TAVI. Thirteen patients had an event during the observational period of 591 days (median). Patients with events had higher LVMI, more severe AR, and worse GLS compared to those without events. Furthermore, receiver-operating curve analysis revealed that GLS was the strongest predictor for clinical events (p = 0.009; area under the curve, 0.73).
CONCLUSION: Preoperative LV geometric deformation and dysfunction, as a consequence of the cumulative burden of pressure overload, improved after TAVI and could predict cardiac events after TAVI.
Предметные рубрики MeSH
AgedAged, 80 and overAortic ValveAortic Valve StenosisEchocardiographyFeasibility StudiesFemaleHeart VentriclesHumansMalePostoperative ComplicationsPredictive Value of TestsPreoperative PeriodPrognosisROC CurveRetrospective StudiesTranscatheter Aortic Valve ReplacementTreatment OutcomeVentricular Dysfunction, Left