MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0202282

Медицинская библиотека · PloS one · 2018

Scanning electron microscopy for blood micro-crystals in aortic stenosis patients.

Wald David S, Tsolaki Elena, Bestwick Jonathan P, Bertazzo Sergio

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Micro-crystals of calcium phosphate have been detected on the aortic valve of patients with aortic stenosis using scanning electron microscopy. It is not known whether crystalisation is specific to heart valve tissue or a general blood-derived process.

METHODS

To this end we modified the method to determine whether calcium phosphate micro-crystals were present in the blood of patients with aortic stenosis. The method was first validated by adding synthetic calcium phosphate hydroxyapatite micro-crystals to healthy volunteer blood samples and determining the lower limit of detection. Then the method was used to examine the blood of 63 patients with echocardiographically confirmed aortic stenosis and 69 unaffected controls undergoing echocardiography for other reasons. Serum calcium and phosphate were measured and the calcium phosphate product compared in cases and controls.

RESULTS

In the validation study, synthetic hydroxyapatite micro-crystals were identified down to a lower concentration limit of 0.008mg/mL. In the experimental study no particles were identified in any patient, with or without aortic stenosis, even though serum calcium phosphate was higher in cases compared with controls 2.6mmol/L (2.58-2.77) versus 2.47mmol/L (2.36-2.57), p = 0.005 for the difference.

CONCLUSION

The results of our study confirm a positive association between serum calcium phosphate and aortic stenosis, but indicate that the calcium phosphate particles found in valve tissue do not precipitate freely in the blood.

Для цитирования: Wald David S, Tsolaki Elena, Bestwick Jonathan P, Bertazzo Sergio. Scanning electron microscopy for blood micro-crystals in aortic stenosis patients.. PloS one. 2018. DOI: 10.1371/journal.pone.0202282.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.