MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1442-9071.2004.00781.x

Медицинская библиотека · Clinical & experimental ophthalmology · 2004

Deposits in artificial corneas: risk factors and prevention.

Hicks Celia R, Chirila Traian V, Werner Liliana, Crawford Geoffrey J, Apple David J, Constable Ian J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To identify risk factors for calcium deposition and pigmented staining within AlphaCor artificial corneas.

METHODS

Retrospective analysis of data from 72 AlphaCor implantations was conducted. Histological analysis of explants was performed.

RESULTS

Eight cases of either intraoptic calcium or pigment deposition occurred in AlphaCor patients between 2.5 and 21 months after implantation. Four cases had diffuse white deposits, confirmed to be calcium and associated with prior coadministration of topical steroids and beta-blockers. The other four cases had brown deposits, associated with cigarette smoking and topical levobunolol.

CONCLUSION

These findings led to changes in patient management protocols, surgeon training and patient information so as to minimize the risk of further occurrences. No further cases of white deposition have occurred after warning surgeons of the risk associated with certain topical therapy combinations. The risk of brown staining may be difficult to remove completely as it appears that environmental exposure to chemicals may cause deposition in addition to personal smoking habits and topical medications.

Для цитирования: Hicks Celia R, Chirila Traian V, Werner Liliana, Crawford Geoffrey J, Apple David J, Constable Ian J. Deposits in artificial corneas: risk factors and prevention.. Clinical & experimental ophthalmology. 2004. DOI: 10.1111/j.1442-9071.2004.00781.x.