MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2013.07.049

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2013

Early experience with off-the-shelf endografts using a zone 0 proximal landing site to treat the ascending aorta and arch.

Bernardes Rodrigo C, Navarro Tulio P, Reis Fernando R, Lima Luiz C M, Monteiro Ernesto L, Procopio Ricardo J, Botelho Francesco E, Dardik Alan

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Acute type A aortic syndromes and its chronic complications are fatal diseases traditionally treated by open surgery, with high mortality rates. An endovascular approach to the ascending aorta could reduce the morbidity and mortality associated with open surgery. Our aim was to report our initial experience in treating ascending aortic pathology using commercially available descending thoracic endografts.

METHODS

From 2007 to 2012, 69 patients presented to our center in Belo Horizonte, Brazil, with acute type A aortic syndrome or its chronic complications. Of the 69 patients, 8 high-risk patients had suitable anatomy, and 7 agreed to participate in the present study.

RESULTS

Of the 7 patients, 4 had penetrating ulcers, 2 had acute dissections, and 1 had chronic dissection with an aneurysm. The technical success rate was 87%, with 1 intraoperative death from acute aortic valve insufficiency. The proximal landing zone was, on average, 21 mm above the aortic valve in all patients. Three patients required intraoperative cervical debranching due to a lesion in the distal third of the ascending aorta, compromising the supra-aortic branches. The distal landing zone was at zone 0 in 4 patients, zone 2 in 1 patient, and in zone 4 in 2 patients. The mean follow-up was 26.3 months. Two repeat dissections developed an average of 2 months after treatment. Both presented with acute dissection that was treated with additional open surgery and both patients survived. Thereafter, no patient had presented again with an acute aortic syndrome or other referable symptoms.

CONCLUSIONS

Endovascular treatment of the ascending aorta is feasible. We had 4 good mid-term results in 7 patients who had presented with penetrating ulcers or aneurysm formation. Acute dissections seem to be more unstable, and additional research is mandatory.

Для цитирования: Bernardes Rodrigo C, Navarro Tulio P, Reis Fernando R, Lima Luiz C M, Monteiro Ernesto L, Procopio Ricardo J, Botelho Francesco E, Dardik Alan. Early experience with off-the-shelf endografts using a zone 0 proximal landing site to treat the ascending aorta and arch.. The Journal of thoracic and cardiovascular surgery. 2013. DOI: 10.1016/j.jtcvs.2013.07.049.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.