MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2013.05.019

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2013

Surgical correction of aortic valve insufficiency after left ventricular assist device implantation.

Atkins B Zane, Hashmi Zubair A, Ganapathi Asvin M, Harrison J Kevin, Hughes G Chad, Rogers Joseph G, Milano Carmelo A

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

New-onset aortic insufficiency (AI) can be encountered after instituting mechanical circulatory support and seems more common and severe with continuous flow (CF) left ventricular assist devices (LVADs) compared with pulsatile devices. Treatment algorithms for de novo, post-LVAD AI have not been well defined. In the present report, we have described 6 patients who underwent aortic valve surgery for new-onset post-LVAD AI.

METHODS

From 2005 to 2011, 271 patients underwent LVAD implantation. Of these LVADs, 225 were CF devices (203 HeartMate II devices, Thoratec Corp, Pleasanton, Calif; and 22 HVAD devices, HeartWare Intl, Inc, Framingham, Mass). The patients were examined for new-onset severe AI requiring surgical intervention.

RESULTS

During follow-up, 6 CF LVAD patients developed new, severe AI that was accompanied by heart failure. After medical therapy had failed, 4 patients underwent redo sternotomy for aortic valve procedures (1 bioprosthetic valve replacement, 1 Dacron patch closure, and 2 aortic valve repairs), and 2 patients underwent transcatheter aortic valve procedure, with 1 requiring revision by open surgery for aortic valve replacement. Of the 6 patients, 5 experienced significant improvement in functional capacity and symptoms. One patient died postoperatively secondary to multiorgan failure and sepsis.

CONCLUSIONS

Surgical treatment of post-LVAD AI with aortic valve oversewing or leaflet repair or by bioprosthetic aortic valve replacement is effective at restoring functional capacity for CF LVAD patients who develop symptomatic, severe AI and can be performed safely with good results. Various transcatheter approaches to these difficult problems are also available and offer less invasive alternatives to conventional surgery.

Для цитирования: Atkins B Zane, Hashmi Zubair A, Ganapathi Asvin M, Harrison J Kevin, Hughes G Chad, Rogers Joseph G, Milano Carmelo A. Surgical correction of aortic valve insufficiency after left ventricular assist device implantation.. The Journal of thoracic and cardiovascular surgery. 2013. DOI: 10.1016/j.jtcvs.2013.05.019.