MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/1475-925x-12-69

Медицинская библиотека · Biomedical engineering online · 2013

Closed-loop real-time simulation model of hemodynamics and oxygen transport in the cardiovascular system.

Broomé Michael, Maksuti Elira, Bjällmark Anna, Frenckner Björn, Janerot-Sjöberg Birgitta

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Computer technology enables realistic simulation of cardiovascular physiology. The increasing number of clinical surgical and medical treatment options imposes a need for better understanding of patient-specific pathology and outcome prediction.

METHODS

A distributed lumped parameter real-time closed-loop model with 26 vascular segments, cardiac modelling with time-varying elastance functions and gradually opening and closing valves, the pericardium, intrathoracic pressure, the atrial and ventricular septum, various pathological states and including oxygen transport has been developed.

RESULTS

Model output is pressure, volume, flow and oxygen saturation from every cardiac and vascular compartment. The model produces relevant clinical output and validation of quantitative data in normal physiology and qualitative directions in simulation of pathological states show good agreement with published data.

CONCLUSION

The results show that it is possible to build a clinically relevant real-time computer simulation model of the normal adult cardiovascular system. It is suggested that understanding qualitative interaction between physiological parameters in health and disease may be improved by using the model, although further model development and validation is needed for quantitative patient-specific outcome prediction.

Для цитирования: Broomé Michael, Maksuti Elira, Bjällmark Anna, Frenckner Björn, Janerot-Sjöberg Birgitta. Closed-loop real-time simulation model of hemodynamics and oxygen transport in the cardiovascular system.. Biomedical engineering online. 2013. DOI: 10.1186/1475-925x-12-69.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.