JACC. Cardiovascular interventions · 2013
Impact of post-implant SAPIEN XT geometry and position on conduction disturbances, hemodynamic performance, and paravalvular regurgitation.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Binder Ronald K, Webb John G, Toggweiler Stefan, Freeman Melanie, Barbanti Marco, Willson Alexander B, Alhassan Donya, Hague Cameron J, Wood David A, Leipsic Jonathon
Аннотация
OBJECTIVES: This report sought to study the impact of the balloon-expandable SAPIEN XT (Edwards Lifesciences, Irvine, California) transcatheter heart valve (THV) stent frame geometry and position on outcomes of transcatheter aortic valve replacement (TAVR).
BACKGROUND: Post-implant THV geometry and position might impact atrioventricular conduction, hemodynamic performance, and annular sealing.
METHODS: Eighty-nine consecutive patients who underwent TAVR with a Sapien XT THV had pre- and post-implant multidetector computed tomography, transthoracic echocardiography, and electrocardiograms performed to assess THV stent geometry, atrioventricular conduction, and hemodynamic performance.
RESULTS: The THV Circularity (THV eccentricity <10% [eccentricity = minimum stent diameter/maximum stent diameter]) and under-expansion (THV area/nominal THV area <90%) were present in 97.8% (2 of 89) and 0%, respectively. Low THV implantation was associated with new left bundle branch block and complete heart block (3.4 ± 2.0 mm vs. 5.5 ± 2.9 mm, p = 0.01) and with the need for permanent pacemaker implantation (3.5 ± 2.0 mm vs. 7.1 ± 2.5 mm, p = 0.001). In contrast, labeled THV size and THV area oversizing was not associated with atrioventricular conduction disturbances. The relation between inflow stent frame area and annular area was related to paravalvular regurgitation (p = 0.025). Labeled prosthesis size but not prosthesis expansion or eccentricity was related to valve gradient (p = 0.005) and effective orifice area (p < 0.001).
CONCLUSIONS: Low implantation depth of balloon-expandable THVs is associated with clinically significant new conduction disturbances and permanent pacemaker implantation. Importantly, annular area oversizing was not associated with these complications.
BACKGROUND: Post-implant THV geometry and position might impact atrioventricular conduction, hemodynamic performance, and annular sealing.
METHODS: Eighty-nine consecutive patients who underwent TAVR with a Sapien XT THV had pre- and post-implant multidetector computed tomography, transthoracic echocardiography, and electrocardiograms performed to assess THV stent geometry, atrioventricular conduction, and hemodynamic performance.
RESULTS: The THV Circularity (THV eccentricity <10% [eccentricity = minimum stent diameter/maximum stent diameter]) and under-expansion (THV area/nominal THV area <90%) were present in 97.8% (2 of 89) and 0%, respectively. Low THV implantation was associated with new left bundle branch block and complete heart block (3.4 ± 2.0 mm vs. 5.5 ± 2.9 mm, p = 0.01) and with the need for permanent pacemaker implantation (3.5 ± 2.0 mm vs. 7.1 ± 2.5 mm, p = 0.001). In contrast, labeled THV size and THV area oversizing was not associated with atrioventricular conduction disturbances. The relation between inflow stent frame area and annular area was related to paravalvular regurgitation (p = 0.025). Labeled prosthesis size but not prosthesis expansion or eccentricity was related to valve gradient (p = 0.005) and effective orifice area (p < 0.001).
CONCLUSIONS: Low implantation depth of balloon-expandable THVs is associated with clinically significant new conduction disturbances and permanent pacemaker implantation. Importantly, annular area oversizing was not associated with these complications.
Предметные рубрики MeSH
AgedAged, 80 and overAortic ValveAortic Valve InsufficiencyAortic Valve StenosisCardiac CatheterizationCardiac Pacing, ArtificialEchocardiographyElectrocardiographyFemaleHeart BlockHeart Conduction SystemHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHemodynamicsHumansMaleMultidetector Computed TomographyPredictive Value of TestsProsthesis DesignRisk AssessmentRisk FactorsSeverity of Illness IndexTreatment Outcome