MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/08941939.2025.2574606

Медицинская библиотека · Journal of investigative surgery : the official journal of the Academy of Surgical Research · 2025

Modified Intrascleral Suture Technique for Repairing Iridodialysis Combined with Phacoemulsification Cataract Surgery.

Liu Rubing, Wang Han, Li Zebin, Kuang Jifa, Luo Furong, Yang Jing, Zeng Mingbing

СтатьяПеревод в очереди

Аннотация

PURPOSE: To introduce a modified intrascleral suture technique (MIST) for repairing iridodialysis combined with phacoemulsification cataract surgery and evaluate its efficacy.

METHODS

We retrospectively analyzed the clinical characteristics and surgical outcomes of patients undergoing iridodialysis repair and cataract surgery (2018-2023). Twelve eyes received MIST, and eleven received the modified sewing-machine technique (MSMT). Both techniques utilized the closed-chamber sewing-machine principle of suture loop formation. MIST utilized a 10-0 polypropylene suture with long straight and short curved needles, guided by a 26-gauge syringe tip for intrascleral suturing. MSMT involved creating a partial-thickness scleral tunnel, through which a prethreaded needle with 10-0 polypropylene suture was passed for fixation.

RESULTS

Iridodialysis was successfully repaired in all patients. The median procedure time was significantly shorter in the MIST group (25 min, IQR: 24.0-27.5) than in the MSMT group (34 min, IQR: 29.0-35.0; p < 0.0001). Although postoperative day 1 best-corrected visual acuity (BCVA) did not differ significantly between groups (p = 0.08), the median BCVA was better in the MIST group (0.1 logMAR, IQR: 0.0-0.4) than the MSMT group (0.4 logMAR, IQR: 0.1-0.6). Complication rates were comparable between groups.

CONCLUSION

The MIST technique provides a minimally invasive alternative for iridodialysis repair by eliminating the need for conjunctival or scleral dissection. This approach significantly reduces operative time while maintaining surgical efficacy and safety, making it a valuable option for combined iridodialysis and cataract surgery.

Для цитирования: Liu Rubing, Wang Han, Li Zebin, Kuang Jifa, Luo Furong, Yang Jing, Zeng Mingbing. Modified Intrascleral Suture Technique for Repairing Iridodialysis Combined with Phacoemulsification Cataract Surgery.. Journal of investigative surgery : the official journal of the Academy of Surgical Research. 2025. DOI: 10.1080/08941939.2025.2574606.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.