MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/21678421.2021.1908362

Медицинская библиотека · Amyotrophic lateral sclerosis & frontotemporal degeneration · 2021

Correlations between measures of ALS respiratory function: is there an alternative to FVC?

Murray Deirdre, Rooney James, Al-Chalabi Amar, Bunte Tommy, Chiwera Theresa, Choudhury Mutahhara, Chio Adriano, Fenton Lauren, Fortune Jennifer, Maidment Lindsay, Manera Umberto, Mcdermott Chris, Meldrum Dara, Meyjes Myrte, Tattersall Rachel, Torrieri Maria Claudia, Van Damme Philip, Vanderlinden Elien, Wood Claire, Van Den Berg Leonard H, Hardiman Orla

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Background

An ongoing longitudinal study in six European sites includes a 3-monthly assessment of forced vital capacity (FVC), slow vital capacity (SVC), peak cough flow (PCF), and Sniff nasal inspiratory pressure (SNIP). The aim of this interim analysis was to assess the potential for SNIP to be a surrogate for aerosol generating procedures given COVID-19 related restrictions.

Methods

This was a prospective observational study. Patients attending six study sites with King's Stage 2 or 3 ALS completed baseline FVC/SVC/SNIP/PCF and repeated assessments 3 monthly. Data were collected from March 2018 to March 2020, after which a COVID-19 related study suspension was imposed. Correlations between the measures were calculated. A Bayesian multiple outcomes random-effects model was constructed to investigate rates of decline across measures.

Results

In total, 270 cases and 828 assessments were included (Mean age 65.2 ± 15.4 years; 32.6% Female; 60% Kings stage 2; 81.1% spinal onset). FVC and SVC were the most closely correlated outcomes (0.95). SNIP showed the least correlation with other metrics 0.53 (FVC), 0.54 (SVC), 0.60 (PCF). All four measures significantly declined over time. SNIP in the bulbar onset group showed the fastest rate of decline. Discussion: SNIP was not well correlated with FVC and SVC, probably because it examines a different aspect of respiratory function. Respiratory measures declined over time, but differentially according to the site of onset. SNIP is not a surrogate for FVC and SVC, but is a complementary measure, declining linearly and differentiating spinal and bulbar onset patients.

Для цитирования: Murray Deirdre, Rooney James, Al-Chalabi Amar, Bunte Tommy, Chiwera Theresa, Choudhury Mutahhara, Chio Adriano, Fenton Lauren, Fortune Jennifer, Maidment Lindsay, Manera Umberto, Mcdermott Chris, Meldrum Dara, Meyjes Myrte, Tattersall Rachel, Torrieri Maria Claudia, Van Damme Philip, Vanderlinden Elien, Wood Claire, Van Den Berg Leonard H, Hardiman Orla. Correlations between measures of ALS respiratory function: is there an alternative to FVC?. Amyotrophic lateral sclerosis & frontotemporal degeneration. 2021. DOI: 10.1080/21678421.2021.1908362.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.