MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10840-022-01440-5

Медицинская библиотека · Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2022

CRT-D replacement strategy: results of the BioCONTINUE study.

Gras Daniel, Clémenty Nicolas, Ploux Sylvain, Guyomar Yves, Legallois Damien, Segreti Luca, Blangy Hugues, Laurent Gabriel, Bizeau Olivier, Fauquembergue Sophie, Lazarus Arnaud, BioCONTINUE study Investigators

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

In patients with cardiac resynchronization therapy defibrillators (CRT-Ds), the need for implantable cardioverter-defibrillator (ICD) back-up may be questionable at time of CRT-D replacement (REP) if ICD implant criteria are no longer met due to an improved left ventricular ejection fraction (LVEF) and if no major ventricular arrhythmic event (VAE) occurred during the CRT-D lifetime. The aim of our study was to assess the relevance of ICD back-up and predictors of VAE after REP in primary prevention CRT-D patients.

METHODS

The prospective, observational, international BioCONTINUE study investigated the rate of patients with at least 1 sustained VAE (sVAE) post-REP and searched for predictive factors of sVAE.

RESULTS

Two hundred seventy-six patients (70 ± 10 years, 77% men, mean LVEF 40.6 ± 12.6%) were followed for 28.4 ± 10.2 months. The rate of patients with sVAE was 8.3%, 10.3%, and 21.2% at 1, 2, and 4 years post-REP. Patients without persistent ICD indication at REP still had a sVAE rate of 5.7% (95% CI 2.3-11.5%) at 2 years. In multivariate analysis, predictive factors of subsequent sVAE were (i) persistent ICD indication (hazard ratio (HR) 3.6; 95% CI 1.6-8.3; p = 0.003); (ii) 64-72 years of age as compared to ≥ 79 years (HR 3.7; 95% CI 1.4-9.7; p = 0.008); and (iii) ischemic heart disease (HR 4.4; 95% CI 2.1-9.3; p < 0.0001).

CONCLUSIONS

The risk of sVAE (21.2% at 4 years post-REP) depends on age, ischemic heart disease, and ICD indication at the time of REP. A non-trivial risk of sVAE remains in patients without persistent ICD indication.

CLINICAL TRIAL REGISTRATION: NCT02323503.

Для цитирования: Gras Daniel, Clémenty Nicolas, Ploux Sylvain, Guyomar Yves, Legallois Damien, Segreti Luca, Blangy Hugues, Laurent Gabriel, Bizeau Olivier, Fauquembergue Sophie, Lazarus Arnaud, BioCONTINUE study Investigators. CRT-D replacement strategy: results of the BioCONTINUE study.. Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. 2022. DOI: 10.1007/s10840-022-01440-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.