m+Medelevator.RU
← Поиск публикаций
Lymphatic research and biology · 2021

Estimation of the Lymph Flow Through Thoracic Duct in Human Subjects Using the Urine Osmolarity: Applicable for Evaluating the Effectiveness of Manual Lymph Drainage.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ohhashi Toshio, Kawai Yoshiko, Hayashi Moyuru, Watanabe-Asaka Tomomi

Аннотация

Currently, there are many methods to evaluate the effectiveness of manual lymph drainage in the treatment of lymphedema, that is, limb volume measurement, bio-electrical impedance measurement, computer tomography, and ultrasound imaging. However, it is difficult for these methods to accurately address the lymph flow generated by manual lymph drainage. Therefore, we aimed at developing a concise and accurate method to measure the lymph flow through the thoracic duct in human subjects, which is applicable for evaluating the effectiveness of manual lymph drainage. In the present mini-review, we demonstrate the developed method in detail and its scientific evidence for the effectiveness obtained with animal and human clinical experiments. In rat in vivo experiments, intragastric administration of distilled water significantly increased mesenteric flow, which was transported via the cisterna chyli and then the thoracic duct. The manual massage on the cisterna chyli in the anesthetized rabbit significantly accelerated the lymph flow through the thoracic duct, resulting in marked hemodilution. Abdominal respiration in the supine position in human subjects produced similar hemodilution, with a marked decrease in the concentration of vasopressin in the blood. On this basis, we developed a new method to accurately measure the lymph flow through the thoracic duct by using changes in the concentration of vasopressin in the blood. In addition, with changes in urine osmolarity depending on the concentration of vasopressin in the blood, we developed a more concise and noninvasive method for evaluating the lymph flow through the thoracic duct in human subjects. These methods may be applicable for evaluating the effectiveness for the manual lymph drainage in the patients with lymphedema.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты