BACKGROUND

The superficial circumflex iliac artery (SCIA) perforator (SCIP) flap has gained acceptance among reconstructive microsurgeons, the minimal donor site morbidity being its greatest advantage. The purpose of this article is to introduce the use of preoperative ultrasonography to facilitate elevation and to avoid postoperative complications of the SCIP flap.

METHODS

Preoperative mapping of the SCIA and the superficial circumflex iliac vein (SCIV) using a high-resolution ultrasound system were performed in patients undergoing reconstruction using a free SCIP flap. The skin paddle was designed placing the SCIA and the SCIV in the middle of the flap.

RESULTS

Preoperatively marked SCIA and SCIV were found intraoperatively in all cases. The skin paddle design for sufficient arterial inflow and venous drainage resulted in no postoperative flap complications.

CONCLUSION

The use of a preoperative high-resolution ultrasound system significantly facilitates elevation of the SCIP flap, notably via the following 2 points: 1) pedicle can always be found under the markings made with preoperative ultrasonography, 2) satisfactory perfusion of the flap can be guaranteed via a safe flap design that includes preoperatively marked vessels within the skin paddle.

Для цитирования: Yoshimatsu Hidehiko, Karakawa Ryo, Fuse Yuma, Hayashi Akitatsu, Yano Tomoyuki. Superficial Circumflex Iliac Artery Perforator Flap Elevation Using Preoperative High-Resolution Ultrasonography for Vessel Mapping and Flap Design.. Journal of reconstructive microsurgery. 2021. DOI: 10.1055/s-0041-1736317.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.