Correlation between glucose measurement parameters of continuous flash monitoring and HbA1c. Real life experience in Asturias.

Pujante Alarcón Pedro, Alonso Felgueroso Carlos, Ares Blanco Jessica, Morales Sánchez Paula, Lambert Goitia Carmen, Rodríguez Escobedo Raúl, Rodríguez Rodero Sandra, Delgado Alvarez Elías, Menéndez Torre Edelmiro Luis

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Despite continuous glucose monitoring having been proven useful in patients with type 1 diabetes mellitus, A1C remains the gold standard for assessing disease management.

MATERIAL AND

METHODS

Descriptive, retrospective study which included 252 patients, 40.5% male, mean age 44.91±14.57 years, mean duration of diabetes 22.21±13.12 years, 88.1% on basal-bolus insulin therapy and 11.9% users of continuous subcutaneous insulin infusion. Glucose measurement, analytical and anthropometric data were obtained.

RESULTS

The mean time in range was 60.18±15.60% and was associated with A1C after adjusting for age, gender, duration of diabetes, BMI, insulin regimen, %CV and time below range (ß: -0.548; p<0.01). The glucose management indicator (GMI) was 7.19±0.69% and was also associated with A1C (ß: 0.957; p<0.01) regardless of age, gender, duration of diabetes, BMI, insulin treatment, %CV and time in range. The average difference between A1C and GMI was 0.17±0.65% (-2.70-3.40%), being higher as A1C increased, in a linear and significant manner, without being influenced by the duration of diabetes or CV.

CONCLUSIONS

Although we found a positive correlation between continuous glucose monitoring glucose measurement parameters and A1C, there is still not enough evidence to replace one parameter with another.

Для цитирования: Pujante Alarcón Pedro, Alonso Felgueroso Carlos, Ares Blanco Jessica, Morales Sánchez Paula, Lambert Goitia Carmen, Rodríguez Escobedo Raúl, Rodríguez Rodero Sandra, Delgado Alvarez Elías, Menéndez Torre Edelmiro Luis. Correlation between glucose measurement parameters of continuous flash monitoring and HbA1c. Real life experience in Asturias.. Endocrinologia, diabetes y nutricion. 2022. DOI: 10.1016/j.endien.2022.08.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.