Медицинская библиотека · The American journal of gastroenterology · 1997

Further classification of dysmotility-like dyspepsia by interdigestive gastroduodenal manometry and plasma motilin level.

Kusano M, Sekiguchi T, Kawamura O, Kikuchi K, Miyazaki M, Tsunoda T, Horikoshi T, Mori M

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To investigate interdigestive gastroduodenal motility with an infused catheter and measure plasma motilin levels in eight normal individuals and 18 patients with dysmotility-like dyspepsia.

METHODS AND

RESULTS

All normal individuals had normal gastroduodenal interdigestive migrating complexes. Patients with dysmotility-like dyspepsia were classified into three subgroups on the basis of gastric antral motility: 1) seven patients with normal interdigestive migrating complexes, 2) five patients without interdigestive migrating complexes and with gastric phase II predominant over phase I, and 3) six patients without interdigestive migrating complexes and with phase I predominance. The maximum and mean plasma motilin levels were significantly different in normal individuals from those in subgroup 3 (Kruskal-Wallis test, p < 0.05).

CONCLUSIONS

Dysmotility-like dyspepsia appears to be a heterogeneous condition. Abnormal motilin secretion may cause dysmotility in subgroup 3, but dyspepsia in subgroup 1 and the absence of interdigestive migrating complexes in subgroup 2 could not be explained only on this basis.

Для цитирования: Kusano M, Sekiguchi T, Kawamura O, Kikuchi K, Miyazaki M, Tsunoda T, Horikoshi T, Mori M. Further classification of dysmotility-like dyspepsia by interdigestive gastroduodenal manometry and plasma motilin level.. The American journal of gastroenterology. 1997.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.