Carotid pseudostring sign from vasa vasorum collaterals.

Kriegshauser J Scott, Patel Maitray D, Nelson Kent D

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To describe the spectral and color Doppler imaging findings in 2 cases of internal carotid artery occlusion with vasa vasorum collateral flow, which we term the "pseudostring sign."

METHODS

Spectral and color Doppler imaging findings in both cases were reviewed. Magnetic resonance angiography in 2 cases and conventional angiography in 1 case were also reviewed.

RESULTS

Both patients had color Doppler images showing that the internal carotid artery was a narrow, stringlike vessel with arterial flow that had normal spectral Doppler features (velocity < 125 cm/s with a normal waveform). Magnetic resonance angiography in 1 patient showed total occlusion of the proximal internal carotid artery with patent vasa vasorum collaterals reconstituting the lumen distally. In the second patient, magnetic resonance angiography showed total occlusion of the proximal internal carotid artery, and conventional angiography showed proximal occlusion with collateral flow through the vasa vasorum.

CONCLUSION

Proximal internal carotid artery occlusion with vasa vasorum collateral flow should be considered when color Doppler imaging shows a seemingly narrow internal carotid artery with tortuosity and normal spectral Doppler features. Patients with these features should not undergo carotid endarterectomy directly on the basis of only the Doppler findings.

Для цитирования: Kriegshauser J Scott, Patel Maitray D, Nelson Kent D. Carotid pseudostring sign from vasa vasorum collaterals.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2003. DOI: 10.7863/jum.2003.22.9.959.