INTRODUCTION

Patients often perceive flexible bronchoscopy as an unpleasant procedure. The aim of this study was to investigate the effect of virtual reality (VR) hypnosis on tolerance to flexible bronchoscopy.

MATERIALS AND

METHODS

We conducted a prospective, randomized, controlled, monocentric study comparing flexible bronchoscopy with VR-induced hypnosis to the usual procedure. Patient tolerance was evaluated using a visual analogue scale (VAS), the state-trait anxiety inventory (STAI) before and after the procedure and, finally, willingness to repeat the examination under the same conditions (WTR).

RESULTS

Among the 70 patients included, 34 were randomized to the VR hypnosis group and 36 to the control group. There was no difference between the 2 groups in terms of modification of the pre-/post-bronchoscopy VAS for anxiety, pain, cough, choking, nausea and overall discomfort, or modification of the STAI score and WTR. Subgroup analysis among patients who were more anxious before the procedure revealed a trend toward reduced anxiety in the VR hypnosis group.

CONCLUSION

This study did not observe any effect of VR hypnosis on the tolerance of patients during routine flexible bronchoscopy. However, VR hypnosis may be beneficial in patients with higher anxiety score before bronchoscopy, a hypothesis that needs to be confirmed by further studies with a larger number of subjects.

Для цитирования: Inthasot V, Taton O, Bondue B, Van Muylem A, Leduc D. [The effects of hypnosis by virtual reality on tolerance to flexible bronchoscopy].. Revue des maladies respiratoires. 2023. DOI: 10.1016/j.rmr.2023.05.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.