MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/a-2499-3468

Медицинская библиотека · Endoscopy international open · 2025

Radiographic, fluoroscopic, and endosonographic predictors of failed EUS-guided transgastric stent placement in patients with Roux-en-Y bypass anatomy.

Moy Benjamin M, Hussain Hero, Yu Jessica X, Platt Kevin D, Machicado Jorge D, Kwon Richard S, Wamsteker Erik-Jan, Philips George M, Schulman Allison R

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND STUDY AIMS: Gastric access temporary for endoscopy (GATE) via endoscopic ultrasound-guided stent placement between the gastric pouch/jejunum and remnant stomach is used in Roux-en-Y gastric bypass (RYGB) to facilitate endoscopic retrograde cholangiopancreatography or other maneuvers. This study aimed to identify radiographic predictors of GATE failure and intraprocedure reasons for aborting.

PATIENTS AND

METHODS

Patients undergoing GATE were matched 3:1 on procedure success. Features indicating quality of the transgastric window were collected including: 1) gastric pouch/blind limb length; 2) location of remnant stomach relative to pouch or blind/roux limb; 3) pouch orientation; 4) remnant orientation; 5) length of contact; 6) tissue thickness; and 7) presence of poor contact (calcification, surgical material, intervening vasculature). Primary outcome was radiographic criteria associated with GATE failure. Secondary outcomes were endoscopic, endosonographic, and fluoroscopic intraprocedure reasons for aborting GATE.

RESULTS

Forty patients (30 successful, 10 aborted, 82.5% female) who underwent GATE were included. Mean (±SD) age and time since RYGB were 62.8±11.9 and 15.1±8.6 years, respectively. There were no group demographic differences. The cumulative number of contact-related risk factors was associated with GATE failure (OR 26.1, 95% CI 0.004-0.337; P =0.004). Two or more factors increased the likelihood of GATE failure ( P <0.05). Echoendoscope angulation/tip deflection, intervening vasculature, distance to remnant stomach, rapid emptying and/or insufficient filling of contrast were reported in cases of GATE failure.

CONCLUSIONS

Radiographic features may predict GATE failure including intervening vasculature or insufficient contact between gastric pouch/blind limb and remnant. Patients demonstrating these features may benefit from alternative treatment approaches early in management.

Для цитирования: Moy Benjamin M, Hussain Hero, Yu Jessica X, Platt Kevin D, Machicado Jorge D, Kwon Richard S, Wamsteker Erik-Jan, Philips George M, Schulman Allison R. Radiographic, fluoroscopic, and endosonographic predictors of failed EUS-guided transgastric stent placement in patients with Roux-en-Y bypass anatomy.. Endoscopy international open. 2025. DOI: 10.1055/a-2499-3468.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.