MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7754/clin.lab.2022.220620

Медицинская библиотека · Clinical laboratory · 2023

Clinical Applicability of Automated Hematology Analyzer Research Parameters for Disease Diagnosis: a Reference Interval Study.

Lee Jiwon, Hong Sangkyoon, Kim Nan Young, Cho Yonggeun, Kim Han-Sung, Kang Hee Jung, Lee Young Kyoung, Kim Miyoung

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

We established reference intervals for research parameters of complete blood cell count and examined their usefulness for diagnosing certain diseases.

METHODS

Reference intervals for 26 basic and 38 research parameters were established for 3,457 and 1,325 men and 2,742 and 830 women aged 20 - 59 and ≥ 60 years, respectively. Research parameter values for patients with iron deficiency anemia (IDA), appendicitis, sepsis, and myelodysplastic syndromes (MDS) were compared against gender- and age-matched reference values.

RESULTS

Seven basic and 10 research parameters among men and one research parameter among women required partitioning by age. No partitioning by gender was required. Further, 67% patients with IDA showed micro red blood cell ratio values above the upper reference limits of their corresponding age and gender subgroups; 3% and 5% patients with appendicitis showed immature granulocyte percentages and counts above the upper reference limits, respectively; 12% - 42% of patients with sepsis showed numerous values exceeded their reference limits, and 67% and 100% patients with MDS showed neutrophil cell complexity and structural dispersion values outside their reference ranges, respectively.

CONCLUSIONS

Overall, < 60% of research parameter values were outside their reference ranges among most patients, indicating their limited diagnostic usefulness.

Для цитирования: Lee Jiwon, Hong Sangkyoon, Kim Nan Young, Cho Yonggeun, Kim Han-Sung, Kang Hee Jung, Lee Young Kyoung, Kim Miyoung. Clinical Applicability of Automated Hematology Analyzer Research Parameters for Disease Diagnosis: a Reference Interval Study.. Clinical laboratory. 2023. DOI: 10.7754/clin.lab.2022.220620.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.