Computed tomography angiography source images closely reflect the integrity of collateral circulation.

Sillanpää Niko, Saarinen Jukka Tapio, Rusanen Harri

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

We studied the interplay between collateral circulation, the location of the thrombus and infarct extent based on evaluation of CT angiography source images (CTA-SI) in predicting the clinical outcome of patients treated with intravenous thrombolytic therapy (<3h) in a retrospective cohort.

METHODS

Anterior circulation occlusion was detected with CTA in 105 patients. The site of the occlusion was recorded, collaterals were assessed with Collateral Score (CS) and Alberta Stroke Program Early CT Score (ASPECTS) was evaluated from CTA-SI, and entered into logistic regression analysis to predict favorable clinical outcome (three-month modified Rankin Scale 0-2).

RESULTS

CTA-SI ASPECTS was highly correlated with CS (Spearman's rho=0.63, P=0.01). Not a single patient with good collaterals (CS 2-4) had a poor CTA-SI scan (ASPECTS 0-7). The mean CTA-SI ASPECTS score became progressively lower when the status of the collateral circulation deteriorated (ANOVA P<0.001). In univariate analysis a good CTA-SI scan at the admission predicted favorable three-month outcome (P<0.001). In a multivariate model containing CTA-SI ASPECTS, CS and the site of the occlusion along with significant clinical parameters, CTA-SI ASPECTS was rendered non-significant (P=0.43) in the presence of CS.

CONCLUSIONS

CTA-SI and CS convey overlapping information. CTA-SI is not a significant predictor of the clinical outcome three months after intravenous thrombolysis when the other CTA-based parameters, CS and the clot location, are considered simultaneously. CTA-SI may have a role in the assessment of the extent of irreversible ischemic changes at admission if contrast injection and image acquisition protocols are designed suitably.

Для цитирования: Sillanpää Niko, Saarinen Jukka Tapio, Rusanen Harri. Computed tomography angiography source images closely reflect the integrity of collateral circulation.. Journal of neuroradiology = Journal de neuroradiologie. 2014. DOI: 10.1016/j.neurad.2014.06.001.