DOI 10.1016/j.ijid.2026.108400
A novel real-time PCR assay for the simultaneous detection of the four main causes of bacterial meningitis.
Аннотация
OBJECTIVES
Current multiplex assays cannot detect all four World Health Organization priority pathogens for meningitis diagnosis (Neisseria meningitidis, Haemophilus influenzae, Streptococcus pneumoniae, and Streptococcus agalactiae). This work developed a novel real-time polymerase chain reaction (PCR) assay capable of simultaneously detecting these pathogens.
METHODS
Forty-four DNA samples, including type cultures (NCTC and ATCC), were tested. Specific primers and probes targeting sodC, to detect N. meningitidis, dmsA for H. influenzae, SP2020 for S. pneumoniae, and cfb for S. agalactiae were evaluated in monoplex and multiplex. Standard curves were generated, and limits of detection (LLD), slope, intercept, and R² were determined. Sensitivity, specificity, and predictive values (positive predictive values/negative predictive values [PPV/NPV]) were assessed for both monoplex and multiplex assays.
RESULTS
Monoplex and multiplex assays showed equivalent performance. Sensitivities were 100% for all targets; specificities ranged 91.7% to 100%, PPVs 72.7% to 100%, and NPVs 100%. The multiplex assay showed high efficiency and consistent amplification for each target gene. LLDs ranged from 24 (S. pneumoniae) to 66 (H. influenzae) genome copies/µl.
CONCLUSION
The multiplex PCR assay showed good performance for rapid and accurate detection of meningitis-associated bacteria. This test has applications for improved diagnosis of meningitis in low- and middle-income countries, where laboratory confirmation of major pathogens such as H. influenzae, S. pneumoniae, N. meningitidis, and Group B Streptococcus remains limited. Field validation with clinical specimens is required before implementation.