MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/eupc.2002.0239

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2002

Interatrial septum pacing avoids the adverse effect of interatrial delay in biventricular pacing: an echo-Doppler evaluation.

Porciani Maria Cristina, Sabini Alessandra, Colella Andrea, Michelucci Antonio, Musilli Nicola, Pieragnoli Paolo, Padeletti Luigi

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: Biventricular pacing (BVP) can improve haemodynamics in patients with dilated cardiomyopathy (DCM) and left bundle branch block by reducing interventricular delay (IVD). Since in DCM interatrial delay (IAD) and IVD frequently coexist, the aim of this study was to test the hypothesis that IVD reduction associated with IAD produces an imbalance between the programmed right atrioventricular (AV) delay and the effective AV delay on the left, and that interatrial septum pacing (IASP) combined with BVP overcomes this adverse effect.

METHODS AND

RESULTS

IAD, IVD, left and right mechanical atrioventricular delay (L-RMAVD) were measured by echo-Doppler in 29 patients with BVP: 17 patients (Group A) had the atrial lead in the right atrial appendage, 12 patients (Group B) who experienced paroxysmal atrial fibrillation had the atrial lead on the interatrial septum. In Group A, LMAVD was significantly shorter than RMAVD (172 +/- 24 vs 207 +/- 24 ms, P<0.002), IAD was significantly longer than IVD (52 +/- 24 vs 21 +/- 18 ms, P<0.0001). In Group B, no differences were observed between LMAVD and RMAVD (187 +/- 32 vs 185 +/- 28 ms, NS), and between IAD and IVD (11 +/- 12 vs 13 +/- 16 ms, NS).

CONCLUSIONS

IAD produces different left and right atrioventricular sequences in BVP. IASP combined with BVP, by resynchronizing both atria and ventricles, is able to avoid this adverse effect.

Для цитирования: Porciani Maria Cristina, Sabini Alessandra, Colella Andrea, Michelucci Antonio, Musilli Nicola, Pieragnoli Paolo, Padeletti Luigi. Interatrial septum pacing avoids the adverse effect of interatrial delay in biventricular pacing: an echo-Doppler evaluation.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2002. DOI: 10.1053/eupc.2002.0239.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.