MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.acra.2012.12.012

Медицинская библиотека · Academic radiology · 2013

7 Tesla MPRAGE imaging of the intracranial arterial vasculature: nonenhanced versus contrast-enhanced.

Umutlu Lale, Theysohn Nina, Maderwald Stefan, Johst Sören, Lauenstein Thomas C, Moenninghoff Christoph, Goericke Sophia L, Dammann Philipp, Wrede Karsten H, Ladd Mark E, Forsting Michael, Schlamann Marc

Сравнительное исследованиеСтатьяTechnical ReportПеревод пока не подготовлен

Аннотация

PURPOSE: To intraindividually compare the delineation of intracranial arterial vasculature in nonenhanced versus contrast-enhanced magnetization prepared rapid gradient echo (MPRAGE) imaging at 7 Tesla (T).

MATERIALS AND

METHODS

Sixteen subjects were examined on a 7 T whole-body magnetic resonance system (Magnetom 7T) equipped with a 32-channel transmit/receive head coil. MPRAGE imaging was performed pre- and postcontrast after the application of 0.1 mmol/kg bodyweight gadobutrol. For qualitative analysis, the delineation of the intracranial arteries, overall image quality, and image impairment were assessed in the nonenhanced and contrast-enhanced datasets using a 5-point scale (5 = excellent to 1 = nondiagnostic). Additionally, contrast ratios (CR) of the middle cerebral artery in correlation to surrounding gray matter in nonenhanced and postcontrast images were obtained. For statistical analysis a Wilcoxon signed-rank test was applied.

RESULTS

Nonenhanced MPRAGE imaging offered an excellent delineation of the central vessel segments of the anterior circulation (mean anterior circulation 4.6) and a moderate- to high-quality assessment of the vessels of the posterior circulation (mean posterior circulation 3.9). Vessel delineation was improved in all assessed segments in the contrast-enhanced datasets, except for the cavernous segment of the internal carotid artery. Quantitative analysis revealed a mild, nonsignificant increase in CR mean values of the M1 segment (CRnonenhanced 0.67; CRcontrast-enhanced 0.69).

CONCLUSION

Our results demonstrate the high diagnostic value of nonenhanced 7 T MPRAGE imaging for the assessment of the intracranial arterial vasculature, with improved assessment of the peripheral segments because of the application of a contrast agent.

Для цитирования: Umutlu Lale, Theysohn Nina, Maderwald Stefan, Johst Sören, Lauenstein Thomas C, Moenninghoff Christoph, Goericke Sophia L, Dammann Philipp, Wrede Karsten H, Ladd Mark E, Forsting Michael, Schlamann Marc. 7 Tesla MPRAGE imaging of the intracranial arterial vasculature: nonenhanced versus contrast-enhanced.. Academic radiology. 2013. DOI: 10.1016/j.acra.2012.12.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.