MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11604-011-0025-8

Медицинская библиотека · Japanese journal of radiology · 2011

Arterial spin-labeling magnetic resonance imaging: the timing of regional maximal perfusion-related signal intensity revealed by a multiphase technique.

Noguchi Tomoyuki, Yoshiura Takashi, Hiwatashi Akio, Togao Osamu, Yamashita Koji, Nagao Eiki, Honda Hiroshi

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: We investigated the time interval from labeling to peak (TLP) of perfusion-signal intensity (SIs) in normal brain using a multiphase arterial spin-labeling (ASL) magnetic resonance imaging (MRI) technique as a fundamental study to assess the temporal characteristics of perfusion SIs.

MATERIALS AND

METHODS

Twenty temporal phases of a pulsed ASL-MRI [QUASAR, quantitative signal targeting by alternating radiofrequency pulses (STAR) labeling of arterial regions] in single-slice imaging were performed in 9 volunteers. Perfusion SIs were measured and TLPs were calculated in 14 regions of interest (ROIs), 7 in each hemisphere: thalamus, lentiform nucleus, medial frontal cortex in the anterior cerebral artery (ACA) territory, temporal cortex in the middle cerebral artery (MCA) territory, medial occipital cortex in the posterior cerebral artery (PCA) territory, anterior watershed region (AWR) and posterior watershed region (PWR).

RESULTS

Mean TLP varied with ROI (region and mean ± standard deviation in seconds): thalamus, 1.60 ± 0.11; lentiform nucleus, 1.52 ± 0.11; ACA territory, 1.53 ± 0.16; MCA territory, 1.59 ± 0.18; PCA territory, 1.68 ± 0.20; AWR, 1.79 ± 0.14; PWR, 2.00 ± 0.20. TLP in the PWR was significantly longer than those in all other regions except the AWR, and TLP in the AWR was significantly longer than those in the lentiform nucleus and the ACA territory.

CONCLUSION

Our results revealed regional differences in the temporal characteristics of perfusion SIs on ASL-MRI.

Для цитирования: Noguchi Tomoyuki, Yoshiura Takashi, Hiwatashi Akio, Togao Osamu, Yamashita Koji, Nagao Eiki, Honda Hiroshi. Arterial spin-labeling magnetic resonance imaging: the timing of regional maximal perfusion-related signal intensity revealed by a multiphase technique.. Japanese journal of radiology. 2011. DOI: 10.1007/s11604-011-0025-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.