MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2019.11.135

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2020

Surgical outcomes of acute type A aortic dissection in patients undergoing cardiopulmonary resuscitation.

Uehara Kyokun, Matsuda Hitoshi, Matsuo Jiro, Inoue Yosuke, Shijo Takayuki, Omura Atsushi, Seike Yoshimasa, Sasaki Hiroaki, Kobayashi Junjiro

СтатьяНаблюдательное исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVES

The surgical indications for acute type A aortic dissection (AAAD) in patients in cardiopulmonary arrest remain controversial. Outcomes of AAAD for patients who underwent cardiopulmonary resuscitation (CPR) were evaluated.

METHODS

Between 2004 and 2018, of the 519 patients who underwent AAAD repair, 34 (6.6%) required CPR before or on starting AAAD repair. The patients were divided into 2 groups, survivors (n = 13) and nonsurvivors (n = 21), to compare the early operative outcomes, including mortality and neurological events.

RESULTS

The major cause of cardiovascular collapse requiring CPR was aortic rupture/cardiac tamponade (n = 21 [61.8%]), followed by coronary malperfusion (n = 12 [35.3%]) and acute aortic valve regurgitation (n = 3 [8.8%]). There were 3 (23.1%) patients in the survivors group and 11 (52.4%) in the nonsurvivors group who required ongoing CPR at the beginning of AAAD repair (P = .039). Of these patients, 1 survivor and 6 nonsurvivors could not achieve return of spontaneous circulation after pericardiotomy (P = .045). Although the duration from onset or arrival to the operating room was similar (P = .35 and P = .49, respectively), overall duration of CPR was shorter in survivors (10 minutes [range, 7.5-16 minutes] vs 16.5 minutes [range, 15-20 minutes]; P = .044). All survivors without any neurological deficits showed return of spontaneous circulation after pericardiotomy. Multivariate regression modeling showed that CPR duration >15 minutes was a significant risk factor for in-hospital mortality (P = .0040).

CONCLUSIONS

CPR duration beyond 15 minutes may be a contraindication for AAAD repair. Moreover, we should reconsider surgery for patients who cannot achieve return of spontaneous circulation after pericardiotomy.

Для цитирования: Uehara Kyokun, Matsuda Hitoshi, Matsuo Jiro, Inoue Yosuke, Shijo Takayuki, Omura Atsushi, Seike Yoshimasa, Sasaki Hiroaki, Kobayashi Junjiro. Surgical outcomes of acute type A aortic dissection in patients undergoing cardiopulmonary resuscitation.. The Journal of thoracic and cardiovascular surgery. 2020. DOI: 10.1016/j.jtcvs.2019.11.135.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.