Transcatheter Aortic Valve Implantation in Patients With Pre-Existing Mechanical Mitral Valve Prostheses.
Аннотация
OBJECTIVES
Transcatheter aortic valve implantation (TAVI) has become standard therapy for aortic stenosis patients with intermediate or high operative risk. Treatment of patients with pre-existing mechanical mitral valve replacement (MVR) is challenging due to possible interference between the TAVI prosthesis and MVR. We present our single-center experience with this special patient cohort.
METHODS
A total of 1960 patients underwent TAVI at our institution between 2009 and March 2018; of these, 16 patients had pre-existing mechanical MVR. Device success and adverse events were analyzed according to the Valve Academic Research Consortium (VARC)-2 criteria. Patients were followed for at least 12 months.
RESULTS
Mean patient age was 81.5 ± 4.4 years. The patients had a mean logistic EuroScore of 37.1 ± 13.5% and STS score of 7.1 ± 3.2%. Successful valve deployment was achieved in all patients, peri-interventional stroke rate was 0.0%, and permanent pacemaker was implanted in 2 patients (12.5%). Two patients experienced major complications, with blockage of the MVR disc in 1 patient and annulus rupture in 1 patient. Hence, 30-day mortality was 12.5% and 1-year mortality was 25.0%.
CONCLUSION
TAVI in patients with mechanical MVR is challenging and requires careful preparation and choice of TAVI device. Repositionable and retrievable devices seem to be a safer option.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.