MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1245/s10434-012-2850-0

Медицинская библиотека · Annals of surgical oncology · 2013

Technical and oncologic safety of robotic thyroid surgery.

Yi Onvox, Yoon Jong Ho, Lee Yu-Mi, Sung Tae-Yon, Chung Ki-Wook, Kim Tae Yong, Kim Won Bae, Shong Young Kee, Ryu Jin-Sook, Hong Suck Joon

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

The aim of this study was to evaluate the surgical outcomes of a double-incision robot-assisted gasless transaxillary thyroidectomy procedure compared with conventional open thyroid surgery.

METHODS

We enrolled and analyzed 521 female patients with classic papillary thyroid carcinoma (PTC) who underwent a total thyroidectomy with central compartment node dissection (CCND) at the Asan Medical Center in Seoul, Korea from December 2008 to December 2010. These patients were classified into robotic (N = 98) or open (N = 423) groups and were compared with respect to clinicopathologic characteristics, complications, and stimulated thyroglobulin (sTg) levels at the time of immediate postoperative radioactive iodine remnant ablation (ablation sTg) and at 6-12 months after the first ablation (control sTg).

RESULTS

The rate of perioperative complications was also similar, except for transient hypoparathyroidism in the robotic group. The median ablation sTg levels (0.39 vs 0.50 ng/mL, P = 0.215) and the proportion of patients with ablation sTg levels <10 ng/mL (94.5 vs 98.0 %, P = 0.103) were also comparable between the robotic and open groups. In addition, the proportion of patients with control sTg levels <1 ng/mL in both robotic and open groups (91.3 vs 95.6 %, P = 0.079) did not show a significant difference.

CONCLUSIONS

Robotic thyroid surgery using a double-incision gasless transaxillary approach is technically safe and may provide a feasible option for a complete thyroid resection and adequate lymph node dissection in patients with PTC.

Для цитирования: Yi Onvox, Yoon Jong Ho, Lee Yu-Mi, Sung Tae-Yon, Chung Ki-Wook, Kim Tae Yong, Kim Won Bae, Shong Young Kee, Ryu Jin-Sook, Hong Suck Joon. Technical and oncologic safety of robotic thyroid surgery.. Annals of surgical oncology. 2013. DOI: 10.1245/s10434-012-2850-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.