MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · The Journal of cardiovascular surgery · 2013

The use of the GORE® TIGRIS® Vascular Stent with dual component design in the superficial femoral and popliteal arteries at 6 months.

Piorkowski M, Freitas B, Schmidt A, Bräunlich S, Ulrich M, Schuster J, Bausback Y, Werner M, Scheinert D

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIM: The aim of this study was to collect procedural and clinical data assessing safety and performance of the GORE® TIGRIS® Vascular Stent, a novel dual component stent, made of a nitinol wire frame combined with a fluoropolymer-interconnecting structure.

METHODS

This retrospective analysis included 32 consecutive patients (20 men, mean age 72.8 years) with 40 atherosclerotic femoropopliteal lesions (occlusions in 5%) who underwent angioplasty and implantation of a GORE® TIGRIS® Vascular Stent. The patients were scheduled for follow-up at 3, 6 and 12 months after stent implantation for Duplex ultrasound and assessment of Rutherford Becker class (RBC) and Ankle-Brachial Index (ABI)

RESULTS

The mean implanted stent length was 62.3 mm (range 30-100 mm). Procedural success (residual stenosis <30%) was achieved in 100% of the lesions. At 6 months 2 restenosis in 2 patients were observed, resulting in a cumulative primary patency rate (±standard error) of 91.7±8.0%. Between baseline and 6 months the ABI increased from 0.65±0.18 to 0.96±0.12 (P<0.0001) and the median of RBC increased from 3 to 1.5 (P<0.0005). No stent thrombosis was found.

CONCLUSION

In this retrospective collection of patients all lesions could be successfully treated with this novel hybrid TIGRIS stent. These preliminary results show promising primary patency rates at 6 months. In addition, significant improvements were observed in symptom classification and hemodynamics.

Для цитирования: Piorkowski M, Freitas B, Schmidt A, Bräunlich S, Ulrich M, Schuster J, Bausback Y, Werner M, Scheinert D. The use of the GORE® TIGRIS® Vascular Stent with dual component design in the superficial femoral and popliteal arteries at 6 months.. The Journal of cardiovascular surgery. 2013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.