Prospective feasibility study on the efficacy and safety of a novel spiral dilator for endoscopic ultrasound-guided drainage.

Ogawa Takahisa, Kanno Yoshihide, Koshita Shinsuke, Kusunose Hiroaki, Sakai Toshitaka, Yonamine Keisuke, Miyamoto Kazuaki, Kozakai Fumisato, Okano Haruka, Anan Hideyuki, Hosokawa Kento, Ito Kei

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

A difficult step in endoscopic ultrasound (EUS)-guided drainage procedures is dilation of the puncture tract before stent deployment. The efficacy and safety of a novel spiral dilator, Tornus ES, for EUS-guided drainage were investigated in this study.

METHODS

This study was conducted as a prospective, single-arm, observational study at Sendai City Medical center. Dilation of the puncture tract using a spiral dilator was attempted for all EUS-guided drainage cases. The primary outcome was the technical success rate which was defined as successful stent placement in the puncture tract. Secondary outcomes were the success rate of dilation using a spiral dilator, procedure time, and adverse events related to the procedures.

RESULTS

A total of 10 patients were enrolled between January and March 2022. Seven patients underwent EUS-guided biliary drainage (hepaticogastrostomy for six and hepaticojejunostomy for one), and the remaining three patients underwent EUS-guided gallbladder drainage. The technical success rate and the success rate of dilation using a spiral dilator were both 100%. The mean procedure time was 27 min. No adverse events related to the procedure occurred in all cases.

CONCLUSIONS

Dilation of the puncture tract using a spiral dilator was effective and safe and might make it easier to perform EUS-guided drainage.

Для цитирования: Ogawa Takahisa, Kanno Yoshihide, Koshita Shinsuke, Kusunose Hiroaki, Sakai Toshitaka, Yonamine Keisuke, Miyamoto Kazuaki, Kozakai Fumisato, Okano Haruka, Anan Hideyuki, Hosokawa Kento, Ito Kei. Prospective feasibility study on the efficacy and safety of a novel spiral dilator for endoscopic ultrasound-guided drainage.. DEN open. 2022. DOI: 10.1002/deo2.170.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.