MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00270-013-0603-5

Медицинская библиотека · Cardiovascular and interventional radiology · 2013

Cutting-balloon angioplasty versus balloon angioplasty as treatment for short atherosclerotic lesions in the superficial femoral artery: randomized controlled trial.

Poncyljusz Wojciech, Falkowski Aleksander, Safranow Krzysztof, Rać Monika, Zawierucha Dariusz

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the treatments of a short-segment atherosclerotic stenosis in the superficial femoral arteries with the cutting balloon angioplasty (CBA) versus conventional balloon angioplasty [percutaneous transluminal angioplasty (PTA)] in a randomized controlled trial.

MATERIAL AND

METHODS

The study group comprised 60 patients (33 men, 27 women; average age 64 years) with a short (≤ 5 cm) focal SFA de novo atherosclerotic stenosis associated with a history of intermittent claudication or rest pain. The primary end point of this study was the rate of binary restenosis in the treated segment 12 months after the intervention. All patients were evenly randomized to either the PTA or CBA treatment arms. Follow-up angiograms and ankle-brachial index (ABI) measurements were performed after 12 months. The evaluation of the restenosis rates and factors influencing its occurrence were calculated by logistic regression analysis.

RESULTS

In the intention-to-treat analysis, restenosis rates after 2-month follow-up were 9 of 30 (30 %) in the PTA group and 4 of 30 (13 %) in the CBA group (p = 0.117). In the actual treatment analysis, after exclusion of patients who required nitinol stent placement for a suboptimal result after angioplasty alone (5 patients in the PTA group and none in the CBA group), restenosis rates were 9 of 25 (36 %) and 4 of 30 (13 %), respectively (p = 0.049). In the intention-to-treat analysis there were also significant differences in ABI values between the PTA and CBA groups at 0.77 ± 0.11 versus 0.82 ± 0.12, respectively (p = 0.039), at 12 months.

CONCLUSION

Based on the presented results of the trial, CBA seems to be a safer and more effective than PTA for treatment of short atherosclerotic lesions in the superior femoral artery.

Для цитирования: Poncyljusz Wojciech, Falkowski Aleksander, Safranow Krzysztof, Rać Monika, Zawierucha Dariusz. Cutting-balloon angioplasty versus balloon angioplasty as treatment for short atherosclerotic lesions in the superficial femoral artery: randomized controlled trial.. Cardiovascular and interventional radiology. 2013. DOI: 10.1007/s00270-013-0603-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.