m+Medelevator.RU
← Поиск публикаций
European journal of nuclear medicine and molecular imaging · 2026

Automated long axial field of view PET image processing and kinetic modelling with the TurBO toolbox.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tuisku Jouni, Palonen Santeri, Kärpijoki Henri, Latva-Rasku Aino, Tuomola Nelli, Harju Harri, Nesterov Sergey V, Oikonen Vesa, Iida Hidehiro, Teuho Jarmo, Han Chunlei, Karjalainen Tomi, Kirjavainen Anna K, Rajader Johan, Klén Riku, Nuutila Pirjo, Knuuti Juhani, Nummenmaa Lauri

Аннотация

PURPOSE: Long axial field of view (LAFOV) PET imaging requires extensive automation due to the large number of target tissues. Therefore, we introduce an open-source analysis pipeline (TurBO, Turku total-BOdy) for automated preprocessing and kinetic modelling of LAFOV [15O]H2O and [18F]FDG PET data. TurBO enables efficient, reproducible quantification of tissue perfusion and metabolism at regional- and voxel-levels through automated co-registration, motion correction, CT-based region of interest (ROI) segmentation, image-derived input function (IDIF) extraction, and region-specific kinetic modelling.

METHODS: The pipeline was validated with Biograph Vision Quadra (Siemens Healthineers) LAFOV PET/CT data from 21 subjects scanned with [15O]H2O and 16 subjects scanned with [18F]FDG. Six CT-segmented ROIs (cortical brain gray matter, left iliopsoas muscle, right kidney cortex and medulla, pancreas, spleen and liver) were used to assess different levels of tissue perfusion and glucose metabolism.

RESULTS: Model fits showed high quality with consistent estimates at regional and voxel-levels (R2 > 0.83 for [15O]H2O, R2 > 0.99 for [18F]FDG). Manual and automated IDIFs were in concordance (R2 > 0.74 for [15O]H2O, and R2 > 0.78 for [18F]FDG) with minimal bias (< 4% and < 10%, respectively). Manual and CT-segmented ROIs showed strong agreement (R2 > 0.82 for [15O]H2O and R2 > 0.83 for [18F]FDG). Motion correction had little impact on estimates (R2 > 0.71 for [15O]H2O and R2 > 0.78 for [18F]FDG) compared with uncorrected data.

CONCLUSION: The TurBO pipeline provides fully automated and reliable quantification for LAFOV PET data. It substantially reduces manual workload and enables standardized, reproducible assessment of inter-organ perfusion and metabolism.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты