m+Medelevator.RU
← Поиск публикаций
Abdominal radiology (New York) · 2024

Material density dual-energy CT images: value added in early diagnosis of peritoneal carcinomatosis : Original research.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Pisuchpen Nisanard, Lennartz Simon, Parakh Anushri, Kongboonvijit Sasiprang, Srinivas Rao Shravya, Pierce Theodore T, Anderson Mark A, Hahn Peter F, Mercaldo Nathaniel D, Kambadakone Avinash

Аннотация

OBJECTIVE: To assess the value of material density (MD) images generated from a rapid kilovoltage-switching dual-energy CT (rsDECT) in early detection of peritoneal carcinomatosis (PC).

MATERIALS AND METHODS: Thirty patients (60 ± 13 years; 24 women) with PC detected on multiple abdominal DECT scans were included. Four separate DECTs with varying findings of PC from each patient were used for qualitative/quantitative analysis, resulting in a total of 120 DECT scans (n = 30 × 4). Three radiologists independently reviewed DECT images (65 keV alone and 65 keV + MD) for diagnosis of PC (diagnostic confidence, lesion conspicuity, sharpness/delineation and image quality) using a 5-point Likert scale. Quantitative estimation of contrast-to-noise ratio (CNR) was done. Wilcoxon signed-rank test and Odds ratio calculation were used to compare between the two protocols. Inter-observer agreement was evaluated using Kappa coefficient analysis. P values < 0.05 were considered statistically significant.

RESULTS: 65 keV + MD images showed a slightly higher sensitivity (89%[95%CI:84,92]) for PC detection compared with 65 keV images alone without statistical significance (84%[95%CI:78,88], p = 0.11) with the experienced reader showing significant improvement (98%[95%CI:93,100] vs. 90%[95%CI:83,94], p = 0.02). On a per-patient basis, use of MD images allowed earlier diagnosis for PC in an additional 13-23% of patients. On sub-group analysis, earlier diagnosis of PC was particularly beneficial in patients with BMI ≤ 29.9 kg/m2. 65 keV + MD images showed higher diagnostic confidence, lesion conspicuity, and lesion sharpness for the experienced reader (p < 0.001). CNR was higher in MD images (1.7 ± 0.5) than 65 keV images (0.1 ± 0.02, p < 0.001). All readers showed moderate interobserver agreement for determining PC by both protocols (κ = 0.58 and κ = 0.47).

CONCLUSION: MD images allow earlier and improved detection of PC with the degree of benefit varying based on reader experience and patient body habitus.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты