MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/ija.ija_783_21

Медицинская библиотека · Indian journal of anaesthesia · 2022

Ultrasound-guided estimation of gastric residual volume using Perlas's formula: A validation study in patients.

Khandekar Sayali S, Doctor Jeson R, Awaskar Shilpa K, Alex Nidhin K, Medha Lipika R, Ranganathan Priya

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND AIMS: Bedside ultrasound (US) is used to evaluate gastric residual volume (GRV) and assess aspiration risk. We examined the accuracy of US-guided measurement of GRV using Perlas's formula, by two trained anaesthesiologists, in patients who had consumed different types and volumes of fluids.

METHODS

Patients with no risk factors for delayed gastric emptying were included. Each assessor independently determined the baseline US-guided GRV. The patients were randomly allocated to receive no drink or 100 or 200 mL of water or milk. US-guided GRV was re-assessed within 5 min after the intervention. Investigators were blinded to the measurements performed by each other and to the randomisation arm. The primary outcome was the agreement between actual volumes consumed and estimated change in GRV.

RESULTS

Agreement between actual volume consumed and estimated change in GRV was poor [Intra-class correlation coefficient (ICC) 0.46, 95% confidence interval (CI) 0.09 to 0.72; P = 0.09 for assessor 1 and ICC 0.37; 95% CI 0.02 to 0.66; P = 0.03 for assessor 2].

CONCLUSION

US-guided GRV measurements using Perlas's formula, performed by trained anaesthesiologists may not be a reliable measure of GRV.

Для цитирования: Khandekar Sayali S, Doctor Jeson R, Awaskar Shilpa K, Alex Nidhin K, Medha Lipika R, Ranganathan Priya. Ultrasound-guided estimation of gastric residual volume using Perlas's formula: A validation study in patients.. Indian journal of anaesthesia. 2022. DOI: 10.4103/ija.ija_783_21.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.