MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1155/2021/9601968

Медицинская библиотека · BioMed research international · 2021

Application of a Cone-Beam Computed Tomography-Based Index for Evaluating Surgical Sites Prior to Sinus Lift Procedures-A Pilot Study.

Shetty Shishir Ram, Arya Satyavrat, Kamath Vinayak, Al-Bayatti Saad, Marei Hesham, Abdelmagyd Hossam, El-Kishawi Mohamed, Al Shehadat Saaid, Al Kawas Sausan, Shetty Raghavendra

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Radiography-based indices can help surgeons perform detailed examinations of the surgical site and predict the surgical difficulty of cases. We aimed to develop and validate a novel CBCT-based index that can predict the surgical difficulty of sinus-augmentation procedures.

MATERIALS AND

METHODS

In the first stage, five experienced dental specialists performed a review of the literature and closed group discussions and designed the novel index. In the next stage, the index was validated. CBCT scans of 30 patients scheduled for sinus-augmentation procedures were evaluated and assigned presurgical CBCT evaluation scores (PSCESs) by five examiners. Subsequently, one oral surgeon performed sinus augmentation using the lateral antrostomy technique and assigned surgical difficulty scores (SDSs) to each of the 30 cases along with 2 observers. The PSCESs and SDSs were statistically analysed to determine the interrater reliability and validity of the index.

RESULTS

The interrater agreement of the PSCES among the five presurgical evaluators was 0.85. The PSCES of the five evaluators had highly significant correlation (P < 0.001, r = 0.68 to 0.76) with the SDS. Regression analysis revealed that for every unit increase in the PSCES, there is 0.46 to 0.57 increase in the SDS value.

CONCLUSION

The results of this pilot study revealed that a novel CBCT-based index can be used as a reliable tool for predicting the surgical difficulty of sinus-augmentation procedures. However, the novel index needs to be tested on a larger sample of patients and evaluators for a more concrete validity and reliability.

Для цитирования: Shetty Shishir Ram, Arya Satyavrat, Kamath Vinayak, Al-Bayatti Saad, Marei Hesham, Abdelmagyd Hossam, El-Kishawi Mohamed, Al Shehadat Saaid, Al Kawas Sausan, Shetty Raghavendra. Application of a Cone-Beam Computed Tomography-Based Index for Evaluating Surgical Sites Prior to Sinus Lift Procedures-A Pilot Study.. BioMed research international. 2021. DOI: 10.1155/2021/9601968.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.