Use of High-Resolution Ultrasonography in Anterior Subcutaneous Transposition of the Ulnar Nerve for Cubital Tunnel Syndrome.
Аннотация
OBJECTIVES
Cubital tunnel syndrome (CTS) is the most common form of ulnar nerve entrapment. In this study, ultrasonography (US) was used not only for diagnosis but also for operation. US findings could be used to establish the diagnosis of CTS and could demonstrate the pathological anatomy in the cubital tunnel region to guide anterior subcutaneous transposition of the ulnar nerve.
METHODS
Sixty-two patients with clinical and electrophysiological evidence of ulnar nerve entrapment were included. All patients received ultrasonographic examination and anterior subcutaneous transposition of the ulnar nerve. The maximal diameter of the ulnar nerve (MDU) was measured in longitudinal views and the range of the hypoechoic area around the nerve was observed. The cross-sectional area (CSA) was also measured on transverse scans. The actual MDU was measured during operation.
RESULTS
The actual MDU was 6.4 ± 0.4 mm, measured during operation. The preoperative MDU was 3.1 ± 0.2 mm. The MDU values recorded in CTS patients were greater than those in normal subjects. The range of the hypoechoic area observed on longitudinal US scans was 2.9-5.6 mm (mean, 4.1 ± 0.4 mm).
CONCLUSIONS
High-resolution US can be used not only in the diagnosis of CTS, also for providing effective preoperative evaluation for the anterior subcutaneous transposition of the ulnar nerve in CTS.