Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

Cianciulli Tomás F, Lax Jorge A, Saccheri María C, Guidoin Robert, Salvado César M, Fernández Adrián J, Prezioso Horacio A

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Для цитирования: Cianciulli Tomás F, Lax Jorge A, Saccheri María C, Guidoin Robert, Salvado César M, Fernández Adrián J, Prezioso Horacio A. Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.. European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology. 2008. DOI: 10.1016/j.euje.2006.08.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.