Медицинская библиотека · Academic radiology · 2006

Reproducibility of CT measurements of aortic valve calcification, mitral annulus calcification, and aortic wall calcification in the multi-ethnic study of atherosclerosis.

Budoff Matthew J, Takasu Junichiro, Katz Ronit, Mao Songshou, Shavelle David M, O'Brien Kevin D, Blumenthal Roger S, Carr J Jeffrey, Kronmal Richard

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПеревод пока не подготовлен

Аннотация

RATIONALE AND

OBJECTIVES

Extracoronary calcifications may have clinical significance. The error in extracoronary calcification measurements is still unknown. Accurate quantification of calcifications of the aortic valve (AVC), mitral annulus (MAC), and aortic wall (AWC) may be possible by using cardiac computed tomography (CT). We sought to establish the interscan, interobserver, and intraobserver reproducibility of these measures in all cardiac CT scans in the Multi-Ethnic Study of Atherosclerosis.

MATERIALS AND

METHODS

We measured extracoronary calcifications in 100 randomly selected participants to assess interobserver, interscan, and intraobserver variability. Two scans were available for analysis in 99 of these participants, and we quantified thoracic aorta and valvular calcifications.

RESULTS

Mean interscan variability of AVC was 9.7% +/- 11.4% and 8% +/- 10.3% for Agatston and volume scores, with variability of the median at 6.4% and 5.5%, respectively (P > .05). MAC inter-reader variability was 8.2% and 8.9%, with interscan variability of 28% and 33% and intrareader variability of 4% and 4.1%, respectively. For AWC, inter-reader variability was 3%-7.1%, interscan variability was 17%-18%, and intrareader variability was 0.4%-1.4%.

CONCLUSION

AVC, MAC, and AWC measurements are sufficiently reproducible to allow serial investigations over a time suitable for clinical studies.

Для цитирования: Budoff Matthew J, Takasu Junichiro, Katz Ronit, Mao Songshou, Shavelle David M, O'Brien Kevin D, Blumenthal Roger S, Carr J Jeffrey, Kronmal Richard. Reproducibility of CT measurements of aortic valve calcification, mitral annulus calcification, and aortic wall calcification in the multi-ethnic study of atherosclerosis.. Academic radiology. 2006. DOI: 10.1016/j.acra.2005.09.090.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.