MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/15266028251359499

Медицинская библиотека · Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2025

Drug-Coated Balloon Versus Plain Balloon Angioplasty for the Treatment of Dysfunctional Dialysis Access: A Systematic Review and Meta-analysis.

Zhang Qianqian, Zou Deshuang, Mao Wenqiong, Su Xing, Li Jingzhen

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

BACKGROUND

The optimal treatment for dysfunctional dialysis access between drug-coated balloon angioplasty (DCBA) and plain balloon angioplasty (PBA), including standard balloon angioplasty (SBA) and high-pressure balloon angioplasty (HPBA), remains unclear. This study aims to compare the efficacy and safety of DCBA and PBA.

MATERIALS AND

METHODS

A systematic review was conducted to identify randomized controlled trials (RCTs) comparing DCBA and PBA. Outcomes included target lesion primary patency (TLPP), access circuit primary patency (ACPP), target lesion revascularization (TLR), technical success, and all-cause mortality. A meta-analysis with a priori subgroup analysis (ie, DCBA vs HPBA and DCBA vs SBA) was performed using a random-effects model to calculate risk ratios (RRs) and 95% confidence intervals (CIs).

RESULTS

Twenty-five RCTs with a total of 2838 patients were included. DCBA showed higher TLPP at 6 months (RR: 1.27, 95% CI: 1.12-1.43, p<0.001) and 12 months (RR: 1.28, 95% CI: 1.13-1.45, p<0.001) than PBA. ACPP was also superior with DCBA at 6 months (RR: 1.25, 95% CI: 1.04-1.40, p=0.002) and 12 months (RR: 1.42, 95% CI: 1.23-1.65, p<0.001). However, no significant difference was found between DCBA and HPBA for TLPP (RR: 1.49, 95% CI: 0.83-2.67, p=0.181) and ACPP (RR: 1.30, 95% CI: 0.92-1.84, p=0.133) at 12 months. TLR was lower with DCBA at 6 months (RR: 0.60, 95% CI: 0.35-0.80, p=0.003) and 12 months (RR: 0.79, 95% CI: 0.68-0.93, p=0.005). No significant difference in the technical success rate and all-cause mortality was observed.

CONCLUSIONS

DCBA improves TLPP and ACPP and reduces the TLR rate compared to PBA. However, it shows no significant advantage over HPBA in terms of TLPP and ACPP at 12 months. The technical success rate and all-cause mortality were similar between the 2 approaches.Clinical ImpactThis meta-analysis highlights the differential effectiveness of drug-coated balloon angioplasty (DCBA) compared with standard balloon angioplasty (SBA) and high-pressure balloon angioplasty (HPBA) in dysfunctional dialysis access. DCBA significantly improves primary patency and reduces revascularization rates compared to SBA, supporting its clinical utility. However, no clear advantage was found over HPBA at 12 months. These results suggest that while DCBA offers benefits over SBA, its added value over HPBA remains uncertain. Clinicians should consider individual patient factors and access characteristics when selecting the optimal angioplasty strategy.

Для цитирования: Zhang Qianqian, Zou Deshuang, Mao Wenqiong, Su Xing, Li Jingzhen. Drug-Coated Balloon Versus Plain Balloon Angioplasty for the Treatment of Dysfunctional Dialysis Access: A Systematic Review and Meta-analysis.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2025. DOI: 10.1177/15266028251359499.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.