m+Medelevator.RU
← Поиск публикаций
Clinical oral investigations · 2025

Flap size as a confounding variable in flap perfusion measurement with the Oxygen-to-see (O2C) analysis system in microvascular head and neck reconstruction - a retrospective analysis.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ooms Mark, Winnand Philipp, Heitzer Marius, Bock Anna, Katz Marie Sophie, Bickenbach Johannes, Hölzle Frank, Modabber Ali

Аннотация

OBJECTIVES: The Oxygen-to-see (O2C) analysis system is used for flap monitoring based on predefined threshold values for flap perfusion. However, flap size may be a confounding variable. The aim of this study was to investigate the relationship between flap size and flap perfusion in microvascular head and neck reconstruction.

MATERIALS AND METHODS: Flap perfusion values measured with the O2C analysis system between 2011 and 2020 in 252 patients undergoing microvascular head and neck reconstruction with a radial free forearm flap (RFFF) or anterolateral thigh flap (ALTF) were retrospectively analyzed. Intraoperative and postoperative flap blood flow, hemoglobin concentration, and hemoglobin oxygen saturation at 8- and 2-mm tissue depths were compared between small (≤ median flap size) and large flaps (> median flap size) for RFFFs and ALTFs separately.

RESULTS: Intraoperative and postoperative hemoglobin concentration at a 2-mm tissue depth differed between small and large ALTFs (65.0 arbitrary units [AU] vs. 51.0 AU, p = 0.007; and 51.5 AU vs. 39.0 AU, p = 0.019). Both differences persisted in multivariable analysis (p < 0.001 and p = 0.012). Other differences were not observed or did not persist in multivariable analysis for RFFFs and ALTFs (all p > 0.05).

CONCLUSIONS: Microvascular free flap perfusion is not related to flap size in terms of flap blood flow and hemoglobin oxygen saturation. This underscores the validity of predefined absolute threshold values in the context of flap monitoring based on perfusion measurement with the O2C analysis system.

CLINICAL RELEVANCE: Flap perfusion measurement with the Oxygen-to-see (O2C) analysis system can be used for flap monitoring of small and large flaps.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты