MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1148/radiology.158.1.3940401

Медицинская библиотека · Radiology · 1986

Sensitivity of double-contrast barium study for left-colon polyps.

Rex D K, Lehman G A, Lappas J C, Miller R E

СтатьяПеревод пока не подготовлен

Аннотация

A blinded, prospective study was conducted to determine the sensitivity of double-contrast barium enema examination (DCBE) in detecting left-colon polyps. Metal clips were endoscopically placed on normal mucosa either adjacent to polyps (in 65 study subjects with 92 polyps) or not adjacent to polyps (in 50 control subjects). DCBE had a high sensitivity for detection of polyps greater than or equal to 1 cm and 6-9 mm in size (100% and 83% detection, respectively) but was insensitive in detecting polyps in the 4 to 5-mm and 2 to 3-mm size ranges (56% and 22% detection, respectively). The factors contributing most commonly to false-negative interpretations were the presence of air bubbles, overlap of bowel loops, and luminal fecal debris. No error in radiographic technique was evident to account for false-negative interpretations in 14 (41%) of 34 polyps that were not detected by DCBE.

Для цитирования: Rex D K, Lehman G A, Lappas J C, Miller R E. Sensitivity of double-contrast barium study for left-colon polyps.. Radiology. 1986. DOI: 10.1148/radiology.158.1.3940401.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.