MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/micc.70045

Медицинская библиотека · Microcirculation (New York, N.Y. : 1994) · 2026

Improved Detection of Capillaries in High-Resolution Handheld Vital Microscopy by Use of the MicroTools Advanced Computer Vision Algorithm.

Guerci Philippe, Ince Can, Dilken Olcay, Belveyre Thibaut, Lapoix Coline, Montomoli Jonathan, Hilty Matthias P

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

OBJECTIVE

Handheld vital microscopy (HVM) enables bedside visualization of the microcirculation, with major improvements from sidestream darkfield (SDF) to incident dark field (IDF) imaging. Although IDF offers high-resolution images, standard analysis methods require down-sampling to match SDF's lower field of view (FOV) and pixel density. MicroTools, an automated stabilization and analysis algorithm, has previously been validated for use with SDF image sequences. This study aimed to assess the accuracy and precision of microcirculatory analysis using MicroTools on full-frame, high-resolution IDF images.

METHODS

Image sequences from a previous study were re-analyzed in both IDF and down-sampled SDF formats. Microcirculatory parameters-including total vessel density (TVD), functional capillary density, and red blood cell velocity (RBCv)-were compared between formats. MicroTools' new stabilization algorithm was also evaluated against existing algorithms.

RESULTS

Full-frame IDF analysis increased the FOV by 200% and pixel density by 66%, enhancing capillary detection and TVD measurements. RBCv values were lower with IDF images. The updated stabilization algorithm showed performance comparable to prior methods.

CONCLUSIONS

MicroTools analysis of full-frame IDF images improved measurement accuracy and vessel detection, with excellent agreement to standard software. Its new stabilization algorithm proved equally robust, supporting broader adoption in clinical research.

Для цитирования: Guerci Philippe, Ince Can, Dilken Olcay, Belveyre Thibaut, Lapoix Coline, Montomoli Jonathan, Hilty Matthias P. Improved Detection of Capillaries in High-Resolution Handheld Vital Microscopy by Use of the MicroTools Advanced Computer Vision Algorithm.. Microcirculation (New York, N.Y. : 1994). 2026. DOI: 10.1111/micc.70045.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.