MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/icorr.2017.8009256

Медицинская библиотека · IEEE ... International Conference on Rehabilitation Robotics : [proceedings] · 2017

Active lower limb orthosis with one degree of freedom for people with paraplegia.

Gloger Michal, Obinata Goro, Genda Eiichi, Babjak Jan, Pei Yanling

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The main challenges of designing devices for paraplegic walking can be summarized into three groups, stability and comfort, high efficiency or low energy consumption, dimensions and weight. A new economical device for people with paraplegia which tackles all problems of the three groups is introduced in this paper. The main idea of this device is based on HALO mechanism. HALO is compact passive medial hip joint orthosis with contralateral hip and ankle linkage, which keeps the feet always parallel to the ground and assists swinging the leg. The medial hip joint is equipped with one actuator in the new design and the new orthosis is called @halo. Due to this update, we can achieve more stable and smoother walking patterns with decreased energy consumption of the users, yet maintain its compact and lightweight features. It is proven by the results from preliminary experiments with able-bodied subjects during which the same device with and without actuator was evaluated. Waddling and excessive vertical elevation of the center of gravity were decreased by 40% with significantly smaller standard deviations in case of the active orthosis. There was 52% less energy spent by the user wearing @halo which was calculated from the vertical excursion difference. There was measured 38.5% bigger impulse in crutches while using passive orthosis. The new @halo device is the first active orthosis for lower limbs with just one actuated degree of freedom for users with paraplegia.

Для цитирования: Gloger Michal, Obinata Goro, Genda Eiichi, Babjak Jan, Pei Yanling. Active lower limb orthosis with one degree of freedom for people with paraplegia.. IEEE ... International Conference on Rehabilitation Robotics : [proceedings]. 2017. DOI: 10.1109/icorr.2017.8009256.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.